Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_10_Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo", uses=false) Using package Buildings with version 10.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|VAVBox_1.damVAV.m_flow",fileNamePrefix="Buildings_10_Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly") translateModel(Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|VAVBox_1.damVAV.m_flow",fileNamePrefix="Buildings_10_Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00124/0.001241, allocations: 103.8 kB / 16.35 MB, free: 5.828 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001159/0.00116, allocations: 189.4 kB / 17.29 MB, free: 5.484 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.325/1.325, allocations: 222.9 MB / 241 MB, free: 15.15 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/package.mo): time 2.403/2.403, allocations: 437.1 MB / 0.7112 GB, free: 4.359 MB / 0.5762 GB Notification: Performance of FrontEnd - loaded program: time 0.001351/0.001351, allocations: 60.41 kB / 0.8707 GB, free: 1.445 MB / 0.6387 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2796/0.281, allocations: 151.6 MB / 1.019 GB, free: 9.855 MB / 0.795 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/ZoneEquipment/Validation/UserProject/Data/AllSystems.mo:22:3-23:32:writable] Warning: Components are deprecated in class. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/ZoneEquipment/Validation/UserProject/Data/AllSystems.mo:25:3-56:38:writable] Warning: Components are deprecated in class. Notification: Performance of NFInst.instantiate(Buildings.Templates.ZoneEquipment.Validation.VAVBoxCoolingOnly): time 0.8004/1.081, allocations: 341 MB / 1.352 GB, free: 3.402 MB / 1.045 GB Notification: Performance of NFInst.instExpressions: time 0.02272/1.104, allocations: 18.8 MB / 1.37 GB, free: 0.5469 MB / 1.061 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002031/1.106, allocations: 59.69 kB / 1.37 GB, free: 500 kB / 1.061 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/ZoneEquipment/Interfaces/PartialAirTerminal.mo:76:3-84:60:writable] Warning: Connector port_Sup is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/ZoneEquipment/Interfaces/PartialAirTerminal.mo:103:3-109:58:writable] Warning: Connector port_Dis is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). Notification: Performance of NFTyping.typeComponents: time 0.004543/1.111, allocations: 1.716 MB / 1.372 GB, free: 14.76 MB / 1.076 GB Notification: Performance of NFTyping.typeBindings: time 0.004075/1.115, allocations: 1.627 MB / 1.373 GB, free: 13.13 MB / 1.076 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:18:3-23:73:writable] Warning: Connector port_a is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Interfaces/PartialTwoPort.mo:24:3-29:71:writable] Warning: Connector port_b is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). Notification: Performance of NFTyping.typeClassSections: time 0.00255/1.117, allocations: 1.008 MB / 1.374 GB, free: 12.13 MB / 1.076 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/Data/AllSystems.mo:30:3-34:96:writable] Warning: Parameter datAll.tit24CliZon has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Controls.OBC.ASHRAE.G36.Types.Title24ClimateZone.Zone_1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Templates/Components/Data/Coil.mo:111:3-117:80:writable] Warning: Parameter datAll.dat_VAVBox_1.coiHea.wAirEnt_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] Error: Parameter VAVBox_1.port_Sup.m_flow has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.001796/1.119, allocations: 1.262 MB / 1.376 GB, free: 10.88 MB / 1.076 GB