Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct -abortSlowSimulation -alarm=480 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Direct.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Direct.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0165447s reading init.xml | | | | | | 0.00150398s reading info.xml | | | | | | 0.000726343s [ 0.7%] pre-initialization | | | | | | 0.000359003s [ 0.4%] initialization | | | | | | 0.000293701s [ 0.3%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00222149s [ 2.3%] creating output-file | | | | | | -2.68668e-21s [ -0.0%] event-handling | | | | | | 0.0114806s [ 11.8%] overhead | | | | | | 0.0819632s [ 84.5%] simulation | | | | | | 0.097049s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 846 steps taken | | | | | | 31254 calls of functionODE | | | | | | 677 evaluations of jacobian | | | | | | 151 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.