Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AixLib_latest_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/package.mo", uses=false) Using package AixLib with version 1.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/package.mo) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=666,variableFilter="",fileNamePrefix="AixLib_latest_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump") translateModel(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=666,variableFilter="",fileNamePrefix="AixLib_latest_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001017/0.001017, allocations: 103.3 kB / 16.35 MB, free: 5.824 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001023/0.001023, allocations: 190.2 kB / 17.29 MB, free: 5.48 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.337/1.337, allocations: 222.9 MB / 241 MB, free: 14.96 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1-master/package.mo): time 0.05843/0.05843, allocations: 12.05 MB / 303.2 MB, free: 3.09 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0005241/0.0005241, allocations: 31.89 kB / 356.3 MB, free: 13.97 MB / 302.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/package.mo): time 1.965/1.965, allocations: 272.3 MB / 0.6657 GB, free: 18.28 MB / 478.1 MB Notification: Performance of FrontEnd - loaded program: time 0.003338/0.003338, allocations: 111.8 kB / 0.7864 GB, free: 12.79 MB / 0.5607 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2317/0.2351, allocations: 109.1 MB / 0.893 GB, free: 15.55 MB / 0.67 GB Notification: Performance of NFInst.instantiate(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.HeatGenerators.HeatPump.HeatPump): time 0.01142/0.2465, allocations: 9.478 MB / 0.9023 GB, free: 6.023 MB / 0.67 GB Notification: Performance of NFInst.instExpressions: time 0.006803/0.2534, allocations: 3.917 MB / 0.9061 GB, free: 2.098 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:73:3-78:26:writable] Warning: Parameter GConIns has annotation(Evaluate=true) and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:106:3-111:26:writable] Warning: Parameter GEvaIns has annotation(Evaluate=true) and no binding. Notification: Performance of NFInst.updateImplicitVariability: time 0.00157/0.255, allocations: 35.88 kB / 0.9062 GB, free: 2.062 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Pumps/FluidSource.mo:21:3-24:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:151:3-154:72:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:155:3-158:70:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:159:3-162:72:writable] Warning: Connector enthalpyPort_a1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:163:3-166:74:writable] Warning: Connector enthalpyPort_b1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:18:5-20:71:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:21:5-23:69:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:18:5-20:71:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:21:5-23:69:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:14:3-16:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:17:3-19:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:14:3-16:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:17:3-19:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Sinks/Vessel.mo:9:3-11:41:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Pumps/Pump.mo:30:3-33:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/Pumps/Pump.mo:34:3-37:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.002076/0.2571, allocations: 0.8728 MB / 0.907 GB, free: 1.191 MB / 0.67 GB Notification: Performance of NFTyping.typeBindings: time 0.001991/0.2591, allocations: 0.6515 MB / 0.9076 GB, free: 0.5352 MB / 0.67 GB Notification: Performance of NFTyping.typeClassSections: time 0.0019/0.261, allocations: 0.9528 MB / 0.9086 GB, free: 15.59 MB / 0.6857 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Obsolete/YearIndependent/FastHVAC/Components/HeatGenerators/HeatPump/HeatPump.mo:73:3-78:26:writable] Error: Parameter heatPump.GConIns has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0001682/0.2612, allocations: 95.41 kB / 0.9087 GB, free: 15.5 MB / 0.6857 GB