Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.2 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Examples.ReverseHeatPump -abortSlowSimulation -alarm=1200 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/Boundaries/PhaseSeparator.mo:41:3-41:139:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((accumulator.x >= 0.0 and accumulator.x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= accumulator.x <= 1.0, has value: 1.28664" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 119.600000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 119.600000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 119.600000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.2.0-main/FlowControl/Internal/PartialValve.mo:35:3-35:108:writable] | | | | The following assertion has been violated at time 119.600000 | | | | ((firstOrder.y <= 1.0 and firstOrder.y >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0515695s reading init.xml | | | | | | 0.00430783s reading info.xml | | | | | | 0.00144625s [ 0.0%] pre-initialization | | | | | | 0.0464138s [ 0.0%] initialization | | | | | | 0.0244957s [ 0.0%] steps | | | | | | 0.117344s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00623268s [ 0.0%] creating output-file | | | | | | 0.118196s [ 0.1%] event-handling | | | | | | 0.0443575s [ 0.0%] overhead | | | | | | 136.486s [ 99.7%] simulation | | | | | | 136.844s [100.0%] total | | | | | events | | | | | | 7 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 4622 steps taken | | | | | | 6290 calls of functionODE | | | | | | 105 evaluations of jacobian | | | | | | 270 error test failures | | | | | | 6 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.