Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 Regular simulation (cvode: SUNDIALS CVODE): ./ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -r=ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank_cvode_res.mat -s cvode LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((flowResistance.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Positive massflow at tank outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 2.392000 | | | | ((staticHead.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Positive massflow at tank outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 2.392000 | | | | ((staticHead.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Negative massflow at tank inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00437173s reading init.xml | | | | | | 0.000474002s reading info.xml | | | | | | 0.00469456s [ 3.9%] pre-initialization | | | | | | 0.000515309s [ 0.4%] initialization | | | | | | 3.1459e-05s [ 0.0%] steps | | | | | | 0.00236403s [ 2.0%] solver (excl. callbacks) | | | | | | 0.000797308s [ 0.7%] creating output-file | | | | | | 1.5442e-05s [ 0.0%] event-handling | | | | | | 0.00807007s [ 6.7%] overhead | | | | | | 0.103301s [ 86.2%] simulation | | | | | | 0.119789s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2784 steps taken | | | | | | 2894 calls of functionODE | | | | | | 48 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.