Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestSwitchValve -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00274914s reading init.xml | | | | | | 0.000198071s reading info.xml | | | | | | 6.2618e-05s [ 0.0%] pre-initialization | | | | | | 0.00166427s [ 0.1%] initialization | | | | | | 0.00252216s [ 0.2%] steps | | | | | | 4.0036e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0458576s [ 3.3%] event-handling | | | | | | 0.0255468s [ 1.8%] overhead | | | | | | 1.30857s [ 94.5%] simulation | | | | | | 1.38426s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 6 time events | | | | | solver: euler | | | | | | 32547 steps taken | | | | | | 32547 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.