Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump") translateModel(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8209/0.8209, allocations: 150.8 MB / 167.1 MB, free: 14.59 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0004218/0.0004221, allocations: 23.97 kB / 206 MB, free: 9.07 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1523/0.1528, allocations: 31.32 MB / 237.3 MB, free: 5.75 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump): time 1.611/1.764, allocations: 295.7 MB / 0.5205 GB, free: 12.07 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.03682/1.801, allocations: 31.78 MB / 0.5516 GB, free: 12.42 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.000335/1.801, allocations: 5.625 kB / 0.5516 GB, free: 12.41 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceAngularVelocity.mo:11:3-15:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005333/1.802, allocations: 164 kB / 0.5517 GB, free: 12.25 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 8.009e-05/1.802, allocations: 37.81 kB / 0.5518 GB, free: 12.22 MB / 446.1 MB