Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./ThermoPower_4.0.0-dev_ThermoPower.Test.GasComponents.TestCompressorInertia -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0076784s reading init.xml | | | | | | 0.000657263s reading info.xml | | | | | | 0.000179567s [ 0.2%] pre-initialization | | | | | | 0.000246262s [ 0.3%] initialization | | | | | | 1.4407e-05s [ 0.0%] steps | | | | | | 0.00369119s [ 5.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.2332e-05s [ 0.0%] event-handling | | | | | | 0.00287904s [ 4.0%] overhead | | | | | | 0.0649409s [ 90.2%] simulation | | | | | | 0.0719636s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2506 steps taken | | | | | | 2509 calls of functionODE | | | | | | 42 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.