Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation: ./ThermoPower_4.0.0-dev_ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_AdaptiveAverageTemp -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00691552s reading init.xml | | | | | | 0.000644098s reading info.xml | | | | | | 0.000174377s [ 0.0%] pre-initialization | | | | | | 0.020809s [ 3.9%] initialization | | | | | | 0.000243958s [ 0.0%] steps | | | | | | 0.00709322s [ 1.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000320498s [ 0.1%] event-handling | | | | | | 0.00920019s [ 1.7%] overhead | | | | | | 0.497838s [ 92.9%] simulation | | | | | | 0.535679s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2533 steps taken | | | | | | 2556 calls of functionODE | | | | | | 44 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.