Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases_Random.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/package.mo", uses=false) Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(ThermalSeparation.Examples.Absorption_IdealGases_Random,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases_Random") translateModel(ThermalSeparation.Examples.Absorption_IdealGases_Random,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Absorption_IdealGases_Random") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001706/0.001706, allocations: 106.9 kB / 17.03 MB, free: 5.656 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001881/0.001881, allocations: 195.9 kB / 17.97 MB, free: 5.062 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.342/1.342, allocations: 222.9 MB / 241.7 MB, free: 15.14 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/package.mo): time 0.3599/0.3599, allocations: 64.93 MB / 356.8 MB, free: 14.74 MB / 302.1 MB Warning: Ignoring unknown experiment annotation option: Algorithm = "Dassl" Notification: Performance of FrontEnd - loaded program: time 0.001437/0.001437, allocations: 67.91 kB / 432 MB, free: 8.797 MB / 350.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1447/0.1461, allocations: 63.54 MB / 495.5 MB, free: 9.184 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/Media/WaterBasedLiquid/BaseClasses/package.mo:6:3-23:32:writable] Error: PartialWaterBased is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/Media/WaterBasedLiquid/N2_O2_H2O.mo:7:3-25:30:writable] Error: Base class ThermalSeparation.Media.WaterBasedLiquid.BaseClasses.PartialWaterBased not found in scope N2_O2_H2O. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation 0.2.0-master/Components/SourcesSinks/SourceLiquid.mo:6:5-6:92:writable] Error: Class MediumLiquid.BaseProperties not found in scope SourceLiquid. Notification: Performance of FrontEnd: time 0.00232/0.1485, allocations: 0.9173 MB / 496.4 MB, free: 8.262 MB / 414.1 MB