Environment - simulationEnvironment: startTime=0 stopTime=15 tolerance=0.0001 numberOfIntervals=2500 stepSize=0.006 Regular simulation: ./ScalableTestGrids_noopt_ScalableTestGrids.Models.Type1.Type1_N_3_M_4 -nls=kinsol -lv=LOG_STATS -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | warning | Command line option 'lv' specified again. Value has been overriden from 'LOG_STATS' to 'LOG_STATS'. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.3/Electrical/Buses/ReferenceBus.mo:22:3-24:100:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(BUS_GEN_EHV_3_2.QSlack) / 1e9 < 0.01)) --> "The reactive power flowing into or out of the reference bus is above 0.01 pu. | | | | You probably need a better setup of excitation voltages, or you can set setPhaseOnly = true. | | | | Please check the documentation of ReferenceBus for further reference" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.3/Electrical/Buses/ReferenceBus.mo:19:3-21:100:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(BUS_GEN_EHV_3_2.PSlack) / 1e9 < 0.01)) --> "The active power flowing into or out of the reference bus is above 0.01 pu. | | | | You probably need a better balancing of the active power generators in the system. | | | | Please check the documentation of ReferenceBus for further reference" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.528027s reading init.xml | | | | | | 0.0575272s reading info.xml | | | | | | 0.00545944s [ 0.3%] pre-initialization | | | | | | 0.030297s [ 1.5%] initialization | | | | | | 0.000278863s [ 0.0%] steps | | | | | | 0.231751s [ 11.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0129415s [ 0.6%] event-handling | | | | | | 0.161362s [ 8.0%] overhead | | | | | | 1.56303s [ 78.0%] simulation | | | | | | 2.00512s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 295 steps taken | | | | | | 562 calls of functionODE | | | | | | 59 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0645402s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.