Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./PowerSysPro_PowerSysPro.Examples.StructuredNetwork.DoubleNetworkWithVariableLoads -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder1.load4.U < feeder1.load4.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder1.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder1.load1.U < feeder1.load1.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder1.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder2.load4.U < feeder2.load4.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder2.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not feeder2.load1.U < feeder2.load1.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetworkWithVariableLoads.feeder2.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:484:11-484:161:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((src.tra2.SA <= 2.5e5)) --> ">>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetworkWithVariableLoads.src.tra2" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00501045s reading init.xml | | | | | | 0.000531436s reading info.xml | | | | | | 5.2269e-05s [ 0.0%] pre-initialization | | | | | | 0.000563416s [ 0.1%] initialization | | | | | | 4.5966e-05s [ 0.0%] steps | | | | | | 9.731e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 5.29396e-23s [ 0.0%] event-handling | | | | | | 0.00192577s [ 0.4%] overhead | | | | | | 0.443256s [ 99.4%] simulation | | | | | | 0.445862s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 5000 steps taken | | | | | | 5000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.