Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2000 stepSize=0.001 Regular simulation: ./Modelica_trunk_Modelica.Thermal.FluidHeatFlow.Examples.TestCylinder -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00155934s reading init.xml | | | | | | 0.000138099s reading info.xml | | | | | | 0.000358432s [ 3.8%] pre-initialization | | | | | | 0.00010111s [ 1.1%] initialization | | | | | | 1.573e-06s [ 0.0%] steps | | | | | | 0.00352015s [ 37.3%] solver (excl. callbacks) | | | | | | 0.000751313s [ 8.0%] creating output-file | | | | | | 4.37082e-21s [ 0.0%] event-handling | | | | | | 0.000820273s [ 8.7%] overhead | | | | | | 0.00374235s [ 39.6%] simulation | | | | | | 0.00946306s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 4018 steps taken | | | | | | 4035 calls of functionODE | | | | | | 69 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.