Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-05 numberOfIntervals=1000 stepSize=0.001 Regular simulation: ./ModelicaTest_trunk_ModelicaTest.Magnetic.FluxTubes.Shapes.FixedShape -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00144326s reading init.xml | | | | | | 0.000168496s reading info.xml | | | | | | 0.00030423s [ 3.3%] pre-initialization | | | | | | 0.00013842s [ 1.5%] initialization | | | | | | 5.641e-06s [ 0.1%] steps | | | | | | 1.283e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000640927s [ 6.9%] creating output-file | | | | | | -1.19114e-21s [ -0.0%] event-handling | | | | | | 0.000301564s [ 3.2%] overhead | | | | | | 0.00788705s [ 84.9%] simulation | | | | | | 0.00929187s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 1000 steps taken | | | | | | 1000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.