Regular simulation: ./ModelicaTest_3.2.2_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpRecirculation -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated at time 0.000000 | | | | pump.delta_head_init >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pump.delta_head_init, has value: -50.3701 LOG_SUCCESS | info | The initialization finished successfully with 4 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00651505s reading init.xml | | | | | | 0.000812977s reading info.xml | | | | | | 0.00100337s [ 0.6%] pre-initialization | | | | | | 0.000610607s [ 0.4%] initialization | | | | | | 1.1822e-05s [ 0.0%] steps | | | | | | 0.0072788s [ 4.6%] solver (excl. callbacks) | | | | | | 0.00520055s [ 3.3%] creating output-file | | | | | | 2.1684e-19s [ 0.0%] event-handling | | | | | | 0.00829305s [ 5.2%] overhead | | | | | | 0.134319s [ 84.1%] simulation | | | | | | 0.160307s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5014 steps taken | | | | | | 5042 calls of functionODE | | | | | | 89 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.