Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./IDEAS_IDEAS.Fluid.FixedResistances.Examples.PlugFlowPipe -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00938321s reading init.xml | | | | | | 0.000811172s reading info.xml | | | | | | 0.000191289s [ 0.5%] pre-initialization | | | | | | 0.000163377s [ 0.4%] initialization | | | | | | 4.789e-06s [ 0.0%] steps | | | | | | 0.00583204s [ 13.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -4.48332e-21s [ -0.0%] event-handling | | | | | | 0.00913544s [ 21.8%] overhead | | | | | | 0.0265079s [ 63.3%] simulation | | | | | | 0.0418797s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5251 steps taken | | | | | | 5513 calls of functionODE | | | | | | 93 evaluations of jacobian | | | | | | 43 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.