Environment - simulationEnvironment: startTime=1e+07 stopTime=1.1e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=400 Regular simulation: ./IDEAS_IDEAS.Examples.Tutorial.Example7 -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpSec.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpPrim.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.227994s reading init.xml | | | | | | 0.0147581s reading info.xml | | | | | | 0.000615454s [ 0.0%] pre-initialization | | | | | | 0.0302316s [ 0.2%] initialization | | | | | | 0.000125375s [ 0.0%] steps | | | | | | 0.957403s [ 7.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.264933s [ 2.1%] event-handling | | | | | | 0.0850729s [ 0.7%] overhead | | | | | | 11.391s [ 89.5%] simulation | | | | | | 12.7294s [100.0%] total | | | | | events | | | | | | 1948 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 58518 steps taken | | | | | | 86075 calls of functionODE | | | | | | 2156 evaluations of jacobian | | | | | | 2759 error test failures | | | | | | 13 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.