Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001685/0.001685, allocations: 112.6 kB / 20.35 MB, free: 1.559 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001929/0.001929, allocations: 191.9 kB / 23.61 MB, free: 5.082 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.517/1.517, allocations: 207.6 MB / 234.3 MB, free: 10.03 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo): time 0.6139/0.6139, allocations: 108.3 MB / 394.9 MB, free: 19.15 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA,tolerance=1e-06,outputFormat="mat",numberOfIntervals=20,variableFilter="time|Gen1.PGenPu|Gen1.QGenPu|Gen1.UPu|Gen2.PGenPu|Gen2.QGenPu|Gen2.UPu|Gen3.PGenPu|Gen3.QGenPu|Gen3.UPu|Gen6.PGenPu|Gen6.QGenPu|Gen6.UPu|Gen8.PGenPu|Gen8.QGenPu|Gen8.UPu|Load2.PPu|Load2.QPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA") translateModel(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA,tolerance=1e-06,outputFormat="mat",numberOfIntervals=20,variableFilter="time|Gen1.PGenPu|Gen1.QGenPu|Gen1.UPu|Gen2.PGenPu|Gen2.QGenPu|Gen2.UPu|Gen3.PGenPu|Gen3.QGenPu|Gen3.UPu|Gen6.PGenPu|Gen6.QGenPu|Gen6.UPu|Gen8.PGenPu|Gen8.QGenPu|Gen8.UPu|Load2.PPu|Load2.QPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002119/0.002119, allocations: 75 kB / 0.5553 GB, free: 52.82 MB / 462.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1232/0.1253, allocations: 77.08 MB / 0.6306 GB, free: 15.58 MB / 478.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA): time 0.02073/0.146, allocations: 18.32 MB / 0.6485 GB, free: 13.17 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.01752/0.1635, allocations: 7.717 MB / 0.656 GB, free: 5.422 MB / 494.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.004499/0.168, allocations: 83.75 kB / 0.6561 GB, free: 5.34 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.004266/0.1723, allocations: 0.9888 MB / 0.6571 GB, free: 4.363 MB / 494.1 MB Notification: Performance of NFTyping.typeBindings: time 0.006203/0.1785, allocations: 1.168 MB / 0.6582 GB, free: 3.188 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:57:5-57:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:59:5-59:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:64:5-64:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:66:5-66:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:71:5-71:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:73:5-73:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:136:3-136:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:137:3-137:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:139:3-139:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:140:3-140:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:142:3-142:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:143:3-143:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:145:3-145:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:146:3-146:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:148:3-148:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:149:3-149:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:151:3-151:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:153:3-153:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:155:3-155:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:157:3-157:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:159:3-159:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:161:3-161:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:163:3-163:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:165:3-165:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:167:3-167:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:169:3-169:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:171:3-171:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:173:3-173:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:175:3-175:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:177:3-177:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:181:3-181:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:183:3-183:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:186:3-186:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:188:3-188:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:190:3-190:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:192:3-192:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:194:3-194:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:196:3-196:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:198:3-198:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:200:3-200:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:202:3-202:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:204:3-204:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:206:3-206:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:208:3-208:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Examples/IEEE14/TestCases/IEEE14CLA.mo:210:3-210:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen1.UPu == Gen1.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen2.UPu == Gen2.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen3.UPu == Gen3.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen6.UPu == Gen6.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen8.UPu == Gen8.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB1B2.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB2B5.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.8.0-master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB1B5.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.009916/0.1884, allocations: 3.202 MB / 0.6613 GB, free: 15.99 MB / 0.4981 GB Notification: Performance of NFFlatten.flatten: time 0.009866/0.1983, allocations: 5.755 MB / 0.667 GB, free: 10.22 MB / 0.4981 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001993/0.2003, allocations: 0.8028 MB / 0.6677 GB, free: 9.367 MB / 0.4981 GB Notification: Performance of NFEvalConstants.evaluate: time 0.003855/0.2041, allocations: 2.313 MB / 0.67 GB, free: 7.047 MB / 0.4981 GB Notification: Performance of NFSimplifyModel.simplify: time 0.003917/0.208, allocations: 2.708 MB / 0.6726 GB, free: 4.328 MB / 0.4981 GB Notification: Performance of NFPackage.collectConstants: time 0.0009591/0.209, allocations: 500 kB / 0.6731 GB, free: 3.84 MB / 0.4981 GB Notification: Performance of NFFlatten.collectFunctions: time 0.0015/0.2105, allocations: 0.7108 MB / 0.6738 GB, free: 3.129 MB / 0.4981 GB Notification: Performance of NFScalarize.scalarize: time 0.001136/0.2116, allocations: 1.266 MB / 0.675 GB, free: 1.859 MB / 0.4981 GB Notification: Performance of NFVerifyModel.verify: time 0.002788/0.2144, allocations: 2.379 MB / 0.6774 GB, free: 15.46 MB / 0.5137 GB Notification: Performance of NFConvertDAE.convert: time 0.007914/0.2223, allocations: 5.841 MB / 0.6831 GB, free: 9.605 MB / 0.5137 GB Notification: Performance of FrontEnd - DAE generated: time 6.432e-06/0.2223, allocations: 0 / 0.6831 GB, free: 9.605 MB / 0.5137 GB Notification: Performance of FrontEnd: time 1.533e-06/0.2223, allocations: 4 kB / 0.6831 GB, free: 9.602 MB / 0.5137 GB Notification: Performance of Transformations before backend: time 0.0001695/0.2225, allocations: 0 / 0.6831 GB, free: 9.602 MB / 0.5137 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 802 * Number of variables: 802 Notification: Performance of Generate backend data structure: time 0.03091/0.2534, allocations: 9.538 MB / 0.6924 GB, free: 15.82 MB / 0.5294 GB Notification: Performance of prepare preOptimizeDAE: time 5.38e-05/0.2535, allocations: 12.03 kB / 0.6924 GB, free: 15.81 MB / 0.5294 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02042/0.2739, allocations: 3.132 MB / 0.6955 GB, free: 12.67 MB / 0.5294 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.00898/0.2829, allocations: 2.941 MB / 0.6983 GB, free: 9.676 MB / 0.5294 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.002015/0.2849, allocations: 2.273 MB / 0.7006 GB, free: 6.965 MB / 0.5294 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001387/0.2863, allocations: 384.2 kB / 0.7009 GB, free: 6.59 MB / 0.5294 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01173/0.298, allocations: 5.14 MB / 0.7059 GB, free: 1.402 MB / 0.5294 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.775e-05/0.2981, allocations: 3.938 kB / 0.7059 GB, free: 1.398 MB / 0.5294 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0005778/0.2986, allocations: 195.8 kB / 0.7061 GB, free: 1.207 MB / 0.5294 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 6.402e-05/0.2987, allocations: 76 kB / 0.7062 GB, free: 1.133 MB / 0.5294 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.009697/0.3084, allocations: 4.198 MB / 0.7103 GB, free: 12.93 MB / 0.545 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04477/0.3532, allocations: 19.73 MB / 0.7296 GB, free: 8.559 MB / 0.5606 GB Notification: Performance of preOpt comSubExp (simulation): time 0.009581/0.3627, allocations: 4.028 MB / 0.7335 GB, free: 4.535 MB / 0.5606 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.006477/0.3692, allocations: 2.726 MB / 0.7362 GB, free: 1.809 MB / 0.5606 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0007091/0.3699, allocations: 67.72 kB / 0.7362 GB, free: 1.742 MB / 0.5606 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.01172/0.3817, allocations: 5.195 MB / 0.7413 GB, free: 12.48 MB / 0.5762 GB Notification: Performance of pre-optimization done (n=666): time 1.3e-05/0.3817, allocations: 0 / 0.7413 GB, free: 12.48 MB / 0.5762 GB Notification: Performance of matching and sorting (n=666): time 0.02968/0.4113, allocations: 11.73 MB / 0.7528 GB, free: 0.6875 MB / 0.5762 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002447/0.4116, allocations: 196.5 kB / 0.7529 GB, free: 496 kB / 0.5762 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00424/0.4158, allocations: 2.381 MB / 0.7553 GB, free: 14.1 MB / 0.5919 GB Notification: Performance of collectPreVariables (initialization): time 0.00116/0.417, allocations: 245.5 kB / 0.7555 GB, free: 13.85 MB / 0.5919 GB Notification: Performance of collectInitialEqns (initialization): time 0.001389/0.4184, allocations: 1.387 MB / 0.7569 GB, free: 12.45 MB / 0.5919 GB Notification: Performance of collectInitialBindings (initialization): time 0.002946/0.4213, allocations: 1.957 MB / 0.7588 GB, free: 10.48 MB / 0.5919 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.00321/0.4245, allocations: 1.043 MB / 0.7598 GB, free: 9.43 MB / 0.5919 GB Notification: Performance of setup shared object (initialization): time 0.0001302/0.4247, allocations: 309.1 kB / 0.7601 GB, free: 9.125 MB / 0.5919 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.005795/0.4305, allocations: 2.606 MB / 0.7626 GB, free: 6.516 MB / 0.5919 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.006958/0.4374, allocations: 4.045 MB / 0.7666 GB, free: 1.918 MB / 0.5919 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.03445/0.4719, allocations: 13.78 MB / 0.78 GB, free: 3.473 MB / 0.6075 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 6.31e-05/0.4719, allocations: 12 kB / 0.78 GB, free: 3.461 MB / 0.6075 GB Notification: Performance of matching and sorting (n=913) (initialization): time 0.3861/0.858, allocations: 11.89 MB / 0.7917 GB, free: 129.8 MB / 0.6075 GB Notification: Performance of prepare postOptimizeDAE: time 8.315e-05/0.8581, allocations: 25.41 kB / 0.7917 GB, free: 129.8 MB / 0.6075 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001043/0.8582, allocations: 39.88 kB / 0.7917 GB, free: 129.8 MB / 0.6075 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01287/0.8711, allocations: 7.574 MB / 0.7991 GB, free: 129.5 MB / 0.6075 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.006793/0.8779, allocations: 1.455 MB / 0.8005 GB, free: 129.4 MB / 0.6075 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01058/0.8885, allocations: 5.374 MB / 0.8058 GB, free: 127.2 MB / 0.6075 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.005567/0.894, allocations: 0.6245 MB / 0.8064 GB, free: 127.1 MB / 0.6075 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0007351/0.8948, allocations: 263.8 kB / 0.8066 GB, free: 127 MB / 0.6075 GB Warning: Assuming fixed start value for the following 118 variables: Gen1.limUQUp:DISCRETE(flow=false start = Gen1.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen1.limUQDown:DISCRETE(flow=false start = Gen1.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQUp:DISCRETE(flow=false start = Gen2.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQDown:DISCRETE(flow=false start = Gen2.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQUp:DISCRETE(flow=false start = Gen3.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQDown:DISCRETE(flow=false start = Gen3.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQUp:DISCRETE(flow=false start = Gen6.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQDown:DISCRETE(flow=false start = Gen6.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQUp:DISCRETE(flow=false start = Gen8.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQDown:DISCRETE(flow=false start = Gen8.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Load2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load2.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load3.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load4.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load5.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load6.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load9.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load10.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load11.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load12.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load13.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load14.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB10B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB10B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB12B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB12B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB13B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB13B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB3B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB3B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB4B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB4B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B12.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B8.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B9.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B10.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo2.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo3.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Bank9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Bank9.State0 fixed = true ) \"Shunt connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) CLAB1B2.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real CLAB2B5.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real CLAB1B5.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real Gen8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen8.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen6.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen3.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen2.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen1.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.running.value:DISCRETE(flow=false start = Gen1.Running0 fixed = true ) type: Boolean Gen2.running.value:DISCRETE(flow=false start = Gen2.Running0 fixed = true ) type: Boolean Gen3.running.value:DISCRETE(flow=false start = Gen3.Running0 fixed = true ) type: Boolean Gen6.running.value:DISCRETE(flow=false start = Gen6.Running0 fixed = true ) type: Boolean Gen8.running.value:DISCRETE(flow=false start = Gen8.Running0 fixed = true ) type: Boolean ModelSignalN.thetaRef:VARIABLE(start = 0.0 unit = \"rad\" fixed = true ) \"Voltage angle reference\" type: Real Load2.running.value:DISCRETE(flow=false start = Load2.Running0 fixed = true ) type: Boolean Load2.UFilteredRawPu:VARIABLE(start = (Load2.u0Pu.re ^ 2.0 + Load2.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load3.running.value:DISCRETE(flow=false start = Load3.Running0 fixed = true ) type: Boolean Load3.UFilteredRawPu:VARIABLE(start = (Load3.u0Pu.re ^ 2.0 + Load3.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load4.running.value:DISCRETE(flow=false start = Load4.Running0 fixed = true ) type: Boolean Load4.UFilteredRawPu:VARIABLE(start = (Load4.u0Pu.re ^ 2.0 + Load4.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load5.running.value:DISCRETE(flow=false start = Load5.Running0 fixed = true ) type: Boolean Load5.UFilteredRawPu:VARIABLE(start = (Load5.u0Pu.re ^ 2.0 + Load5.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load6.running.value:DISCRETE(flow=false start = Load6.Running0 fixed = true ) type: Boolean Load6.UFilteredRawPu:VARIABLE(start = (Load6.u0Pu.re ^ 2.0 + Load6.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load9.running.value:DISCRETE(flow=false start = Load9.Running0 fixed = true ) type: Boolean Load9.UFilteredRawPu:VARIABLE(start = (Load9.u0Pu.re ^ 2.0 + Load9.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load10.running.value:DISCRETE(flow=false start = Load10.Running0 fixed = true ) type: Boolean Load10.UFilteredRawPu:VARIABLE(start = (Load10.u0Pu.re ^ 2.0 + Load10.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load11.running.value:DISCRETE(flow=false start = Load11.Running0 fixed = true ) type: Boolean Load11.UFilteredRawPu:VARIABLE(start = (Load11.u0Pu.re ^ 2.0 + Load11.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load12.running.value:DISCRETE(flow=false start = Load12.Running0 fixed = true ) type: Boolean Load12.UFilteredRawPu:VARIABLE(start = (Load12.u0Pu.re ^ 2.0 + Load12.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load13.running.value:DISCRETE(flow=false start = Load13.Running0 fixed = true ) type: Boolean Load13.UFilteredRawPu:VARIABLE(start = (Load13.u0Pu.re ^ 2.0 + Load13.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load14.running.value:DISCRETE(flow=false start = Load14.Running0 fixed = true ) type: Boolean Load14.UFilteredRawPu:VARIABLE(start = (Load14.u0Pu.re ^ 2.0 + Load14.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real LineB10B11.running.value:DISCRETE(flow=false start = LineB10B11.Running0 fixed = true ) type: Boolean LineB12B13.running.value:DISCRETE(flow=false start = LineB12B13.Running0 fixed = true ) type: Boolean LineB13B14.running.value:DISCRETE(flow=false start = LineB13B14.Running0 fixed = true ) type: Boolean LineB1B2.switchOffSignal2.value:DISCRETE(flow=false start = LineB1B2.SwitchOffSignal20 fixed = true ) type: Boolean LineB1B2.running.value:DISCRETE(flow=false start = LineB1B2.Running0 fixed = true ) type: Boolean LineB1B5.switchOffSignal2.value:DISCRETE(flow=false start = LineB1B5.SwitchOffSignal20 fixed = true ) type: Boolean LineB1B5.running.value:DISCRETE(flow=false start = LineB1B5.Running0 fixed = true ) type: Boolean LineB2B3.running.value:DISCRETE(flow=false start = LineB2B3.Running0 fixed = true ) type: Boolean LineB2B4.running.value:DISCRETE(flow=false start = LineB2B4.Running0 fixed = true ) type: Boolean LineB2B5.switchOffSignal2.value:DISCRETE(flow=false start = LineB2B5.SwitchOffSignal20 fixed = true ) type: Boolean LineB2B5.running.value:DISCRETE(flow=false start = LineB2B5.Running0 fixed = true ) type: Boolean LineB3B4.running.value:DISCRETE(flow=false start = LineB3B4.Running0 fixed = true ) type: Boolean LineB4B5.running.value:DISCRETE(flow=false start = LineB4B5.Running0 fixed = true ) type: Boolean LineB6B11.running.value:DISCRETE(flow=false start = LineB6B11.Running0 fixed = true ) type: Boolean LineB6B12.running.value:DISCRETE(flow=false start = LineB6B12.Running0 fixed = true ) type: Boolean LineB6B13.running.value:DISCRETE(flow=false start = LineB6B13.Running0 fixed = true ) type: Boolean LineB7B8.running.value:DISCRETE(flow=false start = LineB7B8.Running0 fixed = true ) type: Boolean LineB7B9.running.value:DISCRETE(flow=false start = LineB7B9.Running0 fixed = true ) type: Boolean LineB9B10.running.value:DISCRETE(flow=false start = LineB9B10.Running0 fixed = true ) type: Boolean LineB9B14.running.value:DISCRETE(flow=false start = LineB9B14.Running0 fixed = true ) type: Boolean Tfo1.running.value:DISCRETE(flow=false start = Tfo1.Running0 fixed = true ) type: Boolean Tfo2.running.value:DISCRETE(flow=false start = Tfo2.Running0 fixed = true ) type: Boolean Tfo3.running.value:DISCRETE(flow=false start = Tfo3.Running0 fixed = true ) type: Boolean Bank9.running.value:DISCRETE(flow=false start = Bank9.Running0 fixed = true ) type: Boolean CLAB1B2.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB2B5.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB1B5.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB1B5.order.value:DISCRETE(flow=false fixed = true ) type: Integer CLAB2B5.order.value:DISCRETE(flow=false fixed = true ) type: Integer CLAB1B2.order.value:DISCRETE(flow=false fixed = true ) type: Integer Gen8.qStatus:DISCRETE(min = Gen8.QStatus.Standard max = Gen8.QStatus.GenerationMax start = Gen8.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen8.pStatus:DISCRETE(min = Gen8.PStatus.Standard max = Gen8.PStatus.LimitPMax start = Gen8.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen6.qStatus:DISCRETE(min = Gen6.QStatus.Standard max = Gen6.QStatus.GenerationMax start = Gen6.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen6.pStatus:DISCRETE(min = Gen6.PStatus.Standard max = Gen6.PStatus.LimitPMax start = Gen6.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen3.qStatus:DISCRETE(min = Gen3.QStatus.Standard max = Gen3.QStatus.GenerationMax start = Gen3.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen3.pStatus:DISCRETE(min = Gen3.PStatus.Standard max = Gen3.PStatus.LimitPMax start = Gen3.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen2.qStatus:DISCRETE(min = Gen2.QStatus.Standard max = Gen2.QStatus.GenerationMax start = Gen2.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen2.pStatus:DISCRETE(min = Gen2.PStatus.Standard max = Gen2.PStatus.LimitPMax start = Gen2.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen1.qStatus:DISCRETE(min = Gen1.QStatus.Standard max = Gen1.QStatus.GenerationMax start = Gen1.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen1.pStatus:DISCRETE(min = Gen1.PStatus.Standard max = Gen1.PStatus.LimitPMax start = Gen1.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 181 * Number of states: 0 () * Number of discrete variables: 485 ($PRE.Gen1.limUQUp,Gen1.limUQUp,$PRE.Gen1.limUQDown,Gen1.limUQDown,$PRE.Gen2.limUQUp,Gen2.limUQUp,$PRE.Gen2.limUQDown,Gen2.limUQDown,$PRE.Gen3.limUQUp,Gen3.limUQUp,$PRE.Gen3.limUQDown,Gen3.limUQDown,$PRE.Gen6.limUQUp,Gen6.limUQUp,$PRE.Gen6.limUQDown,Gen6.limUQDown,$PRE.Gen8.limUQUp,Gen8.limUQUp,$PRE.Gen8.limUQDown,Gen8.limUQDown,$PRE.Load2.state,Load2.state,$PRE.Load3.state,Load3.state,$PRE.Load4.state,Load4.state,$PRE.Load5.state,Load5.state,$PRE.Load6.state,Load6.state,$PRE.Load9.state,Load9.state,$PRE.Load10.state,Load10.state,$PRE.Load11.state,Load11.state,$PRE.Load12.state,Load12.state,$PRE.Load13.state,Load13.state,$PRE.Load14.state,Load14.state,$PRE.LineB10B11.state,LineB10B11.state,$PRE.LineB12B13.state,LineB12B13.state,$PRE.LineB13B14.state,LineB13B14.state,$PRE.LineB1B2.state,LineB1B2.state,$PRE.LineB1B5.state,LineB1B5.state,$PRE.LineB2B3.state,LineB2B3.state,$PRE.LineB2B4.state,LineB2B4.state,$PRE.LineB2B5.state,LineB2B5.state,$PRE.LineB3B4.state,LineB3B4.state,$PRE.LineB4B5.state,LineB4B5.state,$PRE.LineB6B11.state,LineB6B11.state,$PRE.LineB6B12.state,LineB6B12.state,$PRE.LineB6B13.state,LineB6B13.state,$PRE.LineB7B8.state,LineB7B8.state,$PRE.LineB7B9.state,LineB7B9.state,$PRE.LineB9B10.state,LineB9B10.state,$PRE.LineB9B14.state,LineB9B14.state,$PRE.Tfo1.state,Tfo1.state,$PRE.Tfo2.state,Tfo2.state,$PRE.Tfo3.state,Tfo3.state,$PRE.Bank9.state,Bank9.state,$PRE.CLAB1B2.tOrder,CLAB1B2.tOrder,$PRE.CLAB2B5.tOrder,CLAB2B5.tOrder,$PRE.CLAB1B5.tOrder,CLAB1B5.tOrder,$PRE.Gen8.state,Gen8.converter.u,Gen8.state,$PRE.Gen6.state,Gen6.converter.u,Gen6.state,$PRE.Gen3.state,Gen3.converter.u,Gen3.state,$PRE.Gen2.state,Gen2.converter.u,Gen2.state,$PRE.Gen1.state,Gen1.converter.u,Gen1.state,$PRE.Gen1.running.value,$PRE.Gen2.running.value,$PRE.Gen3.running.value,$PRE.Gen6.running.value,$PRE.Gen8.running.value,$PRE.Load2.running.value,$PRE.Load3.running.value,$PRE.Load4.running.value,$PRE.Load5.running.value,$PRE.Load6.running.value,$PRE.Load9.running.value,$PRE.Load10.running.value,$PRE.Load11.running.value,$PRE.Load12.running.value,$PRE.Load13.running.value,$PRE.Load14.running.value,$PRE.LineB10B11.running.value,$PRE.LineB12B13.running.value,$PRE.LineB13B14.running.value,$PRE.LineB1B2.switchOffSignal2.value,$PRE.LineB1B2.running.value,$PRE.LineB1B5.switchOffSignal2.value,$PRE.LineB1B5.running.value,$PRE.LineB2B3.running.value,$PRE.LineB2B4.running.value,$PRE.LineB2B5.switchOffSignal2.value,$PRE.LineB2B5.running.value,$PRE.LineB3B4.running.value,$PRE.LineB4B5.running.value,$PRE.LineB6B11.running.value,$PRE.LineB6B12.running.value,$PRE.LineB6B13.running.value,$PRE.LineB7B8.running.value,$PRE.LineB7B9.running.value,$PRE.LineB9B10.running.value,$PRE.LineB9B14.running.value,$PRE.Tfo1.running.value,$PRE.Tfo2.running.value,$PRE.Tfo3.running.value,$PRE.Bank9.running.value,$PRE.CLAB1B2.tThresholdReached,$PRE.CLAB2B5.tThresholdReached,$PRE.CLAB1B5.tThresholdReached,$PRE.CLAB1B5.order.value,$PRE.CLAB2B5.order.value,$PRE.CLAB1B2.order.value,$PRE.Gen8.qStatus,$PRE.Gen8.pStatus,$PRE.Gen6.qStatus,$PRE.Gen6.pStatus,$PRE.Gen3.qStatus,$PRE.Gen3.pStatus,$PRE.Gen2.qStatus,$PRE.Gen2.pStatus,$PRE.Gen1.qStatus,$PRE.Gen1.pStatus,CLAB1B5.tThresholdReached,CLAB1B5.order.value,CLAB2B5.tThresholdReached,CLAB2B5.order.value,CLAB1B2.tThresholdReached,CLAB1B2.order.value,Bank9.running.value,Tfo3.running.value,Tfo2.running.value,Tfo1.running.value,LineB9B14.running.value,LineB9B10.running.value,LineB7B9.running.value,LineB7B8.running.value,LineB6B13.running.value,LineB6B12.running.value,LineB6B11.running.value,LineB4B5.running.value,LineB3B4.running.value,LineB2B5.running.value,LineB2B5.switchOffSignal2.value,LineB2B4.running.value,LineB2B3.running.value,LineB1B5.running.value,LineB1B5.switchOffSignal2.value,LineB1B2.running.value,LineB1B2.switchOffSignal2.value,LineB13B14.running.value,LineB12B13.running.value,LineB10B11.running.value,Load14.running.value,Load13.running.value,Load12.running.value,Load11.running.value,Load10.running.value,Load9.running.value,Load6.running.value,Load5.running.value,Load4.running.value,Load3.running.value,Load2.running.value,Gen8.qStatus,Gen8.pStatus,Gen8.running.value,Gen6.qStatus,Gen6.pStatus,Gen6.running.value,Gen3.qStatus,Gen3.pStatus,Gen3.running.value,Gen2.qStatus,Gen2.pStatus,Gen2.running.value,Gen1.qStatus,Gen1.pStatus,Gen1.running.value,$whenCondition2,$whenCondition1,$whenCondition4,$whenCondition3,$whenCondition6,$whenCondition5,$whenCondition7,$whenCondition9,$whenCondition8,$whenCondition10,$whenCondition12,$whenCondition11,$whenCondition13,$whenCondition15,$whenCondition14,$whenCondition16,$whenCondition18,$whenCondition17,$whenCondition19,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,$whenCondition31,$whenCondition33,$whenCondition32,$whenCondition34,$whenCondition36,$whenCondition35,$whenCondition37,$whenCondition39,$whenCondition38,$whenCondition40,$whenCondition42,$whenCondition41,$whenCondition43,$whenCondition45,$whenCondition44,$whenCondition46,$whenCondition48,$whenCondition47,$whenCondition49,$whenCondition51,$whenCondition50,$whenCondition52,$whenCondition54,$whenCondition53,$whenCondition56,$whenCondition55,$whenCondition58,$whenCondition57,$whenCondition59,$whenCondition61,$whenCondition60,$whenCondition62,$whenCondition64,$whenCondition63,$whenCondition66,$whenCondition65,$whenCondition68,$whenCondition67,$whenCondition70,$whenCondition69,$whenCondition72,$whenCondition71,$whenCondition73,$whenCondition75,$whenCondition74,$whenCondition76,$whenCondition78,$whenCondition77,$whenCondition79,$whenCondition81,$whenCondition80,$whenCondition82,$whenCondition84,$whenCondition83,$whenCondition85,$whenCondition87,$whenCondition86,$whenCondition88,$whenCondition90,$whenCondition89,$whenCondition91,$whenCondition93,$whenCondition92,$whenCondition94,$whenCondition96,$whenCondition95,$whenCondition97,$whenCondition99,$whenCondition98,$whenCondition100,$whenCondition102,$whenCondition101,$whenCondition103,$whenCondition105,$whenCondition104,$whenCondition106,$whenCondition108,$whenCondition107,$whenCondition109,$whenCondition111,$whenCondition110,$whenCondition112,$whenCondition114,$whenCondition113,$whenCondition115,$whenCondition117,$whenCondition116,$whenCondition121,$whenCondition120,$whenCondition119,$whenCondition118,$whenCondition126,$whenCondition125,$whenCondition124,$whenCondition123,$whenCondition122,$whenCondition127,$whenCondition129,$whenCondition128,$whenCondition133,$whenCondition132,$whenCondition131,$whenCondition130,$whenCondition138,$whenCondition137,$whenCondition136,$whenCondition135,$whenCondition134,$whenCondition139,$whenCondition141,$whenCondition140,$whenCondition145,$whenCondition144,$whenCondition143,$whenCondition142,$whenCondition150,$whenCondition149,$whenCondition148,$whenCondition147,$whenCondition146,$whenCondition151,$whenCondition153,$whenCondition152,$whenCondition157,$whenCondition156,$whenCondition155,$whenCondition154,$whenCondition162,$whenCondition161,$whenCondition160,$whenCondition159,$whenCondition158,$whenCondition163,$whenCondition165,$whenCondition164,$whenCondition169,$whenCondition168,$whenCondition167,$whenCondition166,$whenCondition174,$whenCondition173,$whenCondition172,$whenCondition171,$whenCondition170,$whenCondition177,$whenCondition176,$whenCondition175,$whenCondition180,$whenCondition179,$whenCondition178,$whenCondition183,$whenCondition182,$whenCondition181,$whenCondition186,$whenCondition185,$whenCondition184,$whenCondition189,$whenCondition188,$whenCondition187,Bank9.switchOffSignal2.value,Bank9.switchOffSignal1.value,Tfo3.switchOffSignal2.value,Tfo3.switchOffSignal1.value,Tfo2.switchOffSignal2.value,Tfo2.switchOffSignal1.value,Tfo1.switchOffSignal2.value,Tfo1.switchOffSignal1.value,LineB9B14.switchOffSignal2.value,LineB9B14.switchOffSignal1.value,LineB9B10.switchOffSignal2.value,LineB9B10.switchOffSignal1.value,LineB7B9.switchOffSignal2.value,LineB7B9.switchOffSignal1.value,LineB7B8.switchOffSignal2.value,LineB7B8.switchOffSignal1.value,LineB6B13.switchOffSignal2.value,LineB6B13.switchOffSignal1.value,LineB6B12.switchOffSignal2.value,LineB6B12.switchOffSignal1.value,LineB6B11.switchOffSignal2.value,LineB6B11.switchOffSignal1.value,LineB4B5.switchOffSignal2.value,LineB4B5.switchOffSignal1.value,LineB3B4.switchOffSignal2.value,LineB3B4.switchOffSignal1.value,LineB2B5.switchOffSignal1.value,LineB2B4.switchOffSignal2.value,LineB2B4.switchOffSignal1.value,LineB2B3.switchOffSignal2.value,LineB2B3.switchOffSignal1.value,LineB1B2.switchOffSignal1.value,LineB1B5.switchOffSignal1.value,LineB13B14.switchOffSignal2.value,LineB13B14.switchOffSignal1.value,LineB12B13.switchOffSignal2.value,LineB12B13.switchOffSignal1.value,LineB10B11.switchOffSignal2.value,LineB10B11.switchOffSignal1.value,Load14.switchOffSignal2.value,Load14.switchOffSignal1.value,Load13.switchOffSignal2.value,Load13.switchOffSignal1.value,Load12.switchOffSignal2.value,Load12.switchOffSignal1.value,Load11.switchOffSignal2.value,Load11.switchOffSignal1.value,Load10.switchOffSignal2.value,Load10.switchOffSignal1.value,Load9.switchOffSignal2.value,Load9.switchOffSignal1.value,Load6.switchOffSignal2.value,Load6.switchOffSignal1.value,Load5.switchOffSignal2.value,Load5.switchOffSignal1.value,Load4.switchOffSignal2.value,Load4.switchOffSignal1.value,Load3.switchOffSignal2.value,Load3.switchOffSignal1.value,Load2.switchOffSignal2.value,Load2.switchOffSignal1.value,Gen8.switchOffSignal3.value,Gen8.switchOffSignal2.value,Gen8.switchOffSignal1.value,Gen6.switchOffSignal3.value,Gen6.switchOffSignal2.value,Gen6.switchOffSignal1.value,Gen3.switchOffSignal3.value,Gen3.switchOffSignal2.value,Gen3.switchOffSignal1.value,Gen2.switchOffSignal3.value,Gen2.switchOffSignal2.value,Gen2.switchOffSignal1.value,Gen1.switchOffSignal3.value,Gen1.switchOffSignal2.value,Gen1.switchOffSignal1.value,CLAB1B5.AutomatonExists.value,CLAB2B5.AutomatonExists.value,CLAB1B2.AutomatonExists.value) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (728): * Single equations (assignments): 727 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(115,71)} Notification: Performance of prepare postOptimizeDAE: time 0.003237/0.898, allocations: 1.624 MB / 0.8082 GB, free: 126.2 MB / 0.6075 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001173/0.8992, allocations: 0.5584 MB / 0.8088 GB, free: 126.2 MB / 0.6075 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.02095/0.9201, allocations: 10.33 MB / 0.8189 GB, free: 120.2 MB / 0.6075 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 9.433e-05/0.9202, allocations: 35.88 kB / 0.8189 GB, free: 120.2 MB / 0.6075 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.291e-05/0.9202, allocations: 3.938 kB / 0.8189 GB, free: 120.2 MB / 0.6075 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001169/0.9214, allocations: 0.5055 MB / 0.8194 GB, free: 120 MB / 0.6075 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001128/0.9225, allocations: 192.2 kB / 0.8196 GB, free: 119.8 MB / 0.6075 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.003902/0.9264, allocations: 425.4 kB / 0.82 GB, free: 119.6 MB / 0.6075 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001463/0.9279, allocations: 0.6483 MB / 0.8206 GB, free: 119.1 MB / 0.6075 GB Notification: Performance of postOpt createDAEmodeBDAE (simulation): time 0.02056/0.9484, allocations: 9.537 MB / 0.8299 GB, free: 109.7 MB / 0.6075 GB Notification: Performance of postOpt symbolicJacobianDAE (simulation): time 0.01508/0.9635, allocations: 10.35 MB / 0.84 GB, free: 99.23 MB / 0.6075 GB Notification: Performance of postOpt setEvaluationStage (simulation): time 0.00449/0.968, allocations: 2.759 MB / 0.8427 GB, free: 96.45 MB / 0.6075 GB Notification: Performance of sorting global known variables: time 0.001703/0.9697, allocations: 1.47 MB / 0.8442 GB, free: 94.98 MB / 0.6075 GB Notification: Performance of Backend: time 4.6e-07/0.9697, allocations: 0 / 0.8442 GB, free: 94.98 MB / 0.6075 GB Notification: Performance of simCode: created initialization part: time 0.01447/0.9842, allocations: 5.138 MB / 0.8492 GB, free: 89.87 MB / 0.6075 GB Notification: Performance of SimCode: time 0.0123/0.9965, allocations: 9.72 MB / 0.8587 GB, free: 80.2 MB / 0.6075 GB Notification: Performance of Templates: time 0.1485/1.145, allocations: 105.8 MB / 0.962 GB, free: 6.812 MB / 0.6387 GB " [Timeout remaining time 659] make -j1 -f Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.makefile [Timeout 660] (rm -f Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.pipe ; mkfifo Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.pipe ; head -c 1048576 < Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.pipe >> ../files/Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.sim & ./Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA -ls=klu -lv=LOG_STATS -nls=kinsol -s=euler -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS > Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.pipe 2>&1) [Timeout 480] diffSimulationResults("Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA_res.mat","/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ReferenceFiles/Dynawo/dynawo/sources/Models/Modelica/Dynawo/Examples/references/Dynawo.Examples.IEEE14.TestCases.IEEE14CLA_res.csv","/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.diff",relTol=0.003,relTolDiffMinMax=0.003,rangeDelta=0.001) [Timeout 660] "Warning: Resultfile and Reference have different end time points! Reffile[506]=1.000000 File[40]=200.000000 " [Timeout remaining time 660] Reference file matches [Calling sys.exit(0), Time elapsed: 9.948389188852161]