Environment - simulationEnvironment: startTime=0 stopTime=300 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.12 Regular simulation: ./ClaRa_dev_ClaRa.Components.Electrical.Check.TestTurboGenerator -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00794504s reading init.xml | | | | | | 0.00062393s reading info.xml | | | | | | 0.00666336s [ 6.8%] pre-initialization | | | | | | 0.0424722s [ 43.3%] initialization | | | | | | 6.181e-06s [ 0.0%] steps | | | | | | 0.00458368s [ 4.7%] solver (excl. callbacks) | | | | | | 0.0067363s [ 6.9%] creating output-file | | | | | | 9.996e-06s [ 0.0%] event-handling | | | | | | 0.00377397s [ 3.8%] overhead | | | | | | 0.0339081s [ 34.5%] simulation | | | | | | 0.0981537s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5015 steps taken | | | | | | 5031 calls of functionODE | | | | | | 86 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.