Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./ClaRa_ClaRa.Components.VolumesValvesFittings.Fittings.Check.Test_Junction -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/VolumesValvesFittings/Fittings/FlueGasJunction_L2.mo:28:5-28:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flueGasJunction2.summary.gas.H >= 0.0)) --> "Variable violating min constraint: 0.0 <= flueGasJunction2.summary.gas.H, has value: -1.13184" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/VolumesValvesFittings/Fittings/FlueGasJunction_L2.mo:28:5-28:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flueGasJunction3.summary.gas.H >= 0.0)) --> "Variable violating min constraint: 0.0 <= flueGasJunction3.summary.gas.H, has value: -1.14656" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Basics/ControlVolumes/GasVolumes/VolumeGas_L2.mo:121:5-121:85:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flueGasCell1.summary.outline.H >= 0.0)) --> "Variable violating min constraint: 0.0 <= flueGasCell1.summary.outline.H, has value: -1.14656" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/VolumesValvesFittings/Fittings/FlueGasJunction_L2.mo:28:5-28:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flueGasJunction1.summary.gas.H >= 0.0)) --> "Variable violating min constraint: 0.0 <= flueGasJunction1.summary.gas.H, has value: -0.114656" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/VolumesValvesFittings/Fittings/FlueGasJunction_L2.mo:28:5-28:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flueGasJunction.summary.gas.H >= 0.0)) --> "Variable violating min constraint: 0.0 <= flueGasJunction.summary.gas.H, has value: -0.114656" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.099289s reading init.xml | | | | | | 0.00762056s reading info.xml | | | | | | 0.000565841s [ 0.0%] pre-initialization | | | | | | 0.04099s [ 3.1%] initialization | | | | | | 0.000219753s [ 0.0%] steps | | | | | | 0.0470544s [ 3.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000738715s [ 0.1%] event-handling | | | | | | 0.0140401s [ 1.1%] overhead | | | | | | 1.21754s [ 92.2%] simulation | | | | | | 1.32115s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5322 steps taken | | | | | | 5613 calls of functionODE | | | | | | 97 evaluations of jacobian | | | | | | 39 error test failures | | | | | | 2 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.