Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.Infiltration -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.03.16 05:31 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.03.16 05:31 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defInf.duc.m_flow >= 0.0 and defInf.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= defInf.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((higInf.duc.m_flow >= 0.0 and higInf.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= higInf.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0708817s reading init.xml | | | | | | 0.00583511s reading info.xml | | | | | | 0.00123647s [ 0.0%] pre-initialization | | | | | | 14.3569s [ 96.3%] initialization | | | | | | 4.2941e-05s [ 0.0%] steps | | | | | | 0.0617235s [ 0.4%] solver (excl. callbacks) | | | | | | 0.00957896s [ 0.1%] creating output-file | | | | | | 0.119449s [ 0.8%] event-handling | | | | | | 0.0325442s [ 0.2%] overhead | | | | | | 0.322595s [ 2.2%] simulation | | | | | | 14.9041s [100.0%] total | | | | | events | | | | | | 145 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5566 steps taken | | | | | | 6081 calls of functionODE | | | | | | 148 evaluations of jacobian | | | | | | 4 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 7.92sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.81sec EnergyPlus Completed Successfully.