Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.03.16 05:30 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalTwoZoneBuildings.bui.inf1.y has in Modelica the unit 1. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0257301s reading init.xml | | | | | | 0.00210071s reading info.xml | | | | | | 0.000610825s [ 0.0%] pre-initialization | | | | | | 7.07973s [ 97.1%] initialization | | | | | | 1.7052e-05s [ 0.0%] steps | | | | | | 0.0146879s [ 0.2%] solver (excl. callbacks) | | | | | | 0.00526792s [ 0.1%] creating output-file | | | | | | 0.068321s [ 0.9%] event-handling | | | | | | 0.0109734s [ 0.2%] overhead | | | | | | 0.113591s [ 1.6%] simulation | | | | | | 7.2932s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5697 steps taken | | | | | | 6657 calls of functionODE | | | | | | 288 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.38sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. corrupted size vs. prev_size in fastbins