Environment - simulationEnvironment: startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_latest_Buildings.Obsolete.Fluid.Movers.Validation.ControlledFlowMachine -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:98:3-98:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eta, has value: -2.19301e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eff.yMot, has value: -3.98868e-34" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:98:3-98:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eta, has value: -1.62509e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eff.yMot, has value: -2.95574e-31" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Obsolete/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((fan4.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.eta, has value: -2.09125e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((fan4.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.eff.yMot, has value: -3.80359e-14" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0333154s reading init.xml | | | | | | 0.00289475s reading info.xml | | | | | | 0.00111704s [ 1.1%] pre-initialization | | | | | | 0.000904847s [ 0.9%] initialization | | | | | | 0.000137688s [ 0.1%] steps | | | | | | 0.00984321s [ 9.3%] solver (excl. callbacks) | | | | | | 0.00325691s [ 3.1%] creating output-file | | | | | | 0.000927024s [ 0.9%] event-handling | | | | | | 0.0113733s [ 10.8%] overhead | | | | | | 0.0777476s [ 73.8%] simulation | | | | | | 0.105308s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5694 steps taken | | | | | | 5778 calls of functionODE | | | | | | 99 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.