Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=240 stepSize=3600 Regular simulation: ./Buildings_latest_Buildings.Obsolete.Air.Systems.SingleZone.VAV.Examples.Guideline36 -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Obsolete/Controls/OBC/ASHRAE/G36_PR1/AHUs/SingleZone/VAV/Economizers/Controller.mo:222:3-229:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.conEco.VOutMinSet_flow >= max(con.conEco.damLim.VOutMin_flow, max(0.0, con.conEco.VOutMin_flow)) and con.conEco.VOutMinSet_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow))) --> "Variable violating min/max constraint: max(con.conEco.damLim.VOutMin_flow, max(0.0, con.conEco.VOutMin_flow)) <= con.conEco.VOutMinSet_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow), has value: 0" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Interfaces/ConservationEquation.mo:104:3-105:46:writable] | | | | The following assertion has been violated at time 63000.000000 | | | | ((hvac.chi.vol1.dynBal.mC[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.chi.vol1.dynBal.mC[1], has value: -3.81555e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Interfaces/ConservationEquation.mo:108:3-109:38:writable] | | | | The following assertion has been violated at time 63000.000000 | | | | ((hvac.chi.vol1.dynBal.C[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.chi.vol1.dynBal.C[1], has value: -1.08264e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 406856.305253 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -4.34223e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Obsolete/Controls/OBC/ASHRAE/G36_PR1/AHUs/SingleZone/VAV/Economizers/Subsequences/Modulation.mo:85:3-90:57:writable] | | | | The following assertion has been violated at time 741600.000000 | | | | ((con.conEco.mod.yOutDamPos >= 0.0 and con.conEco.mod.yOutDamPos <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= con.conEco.mod.yOutDamPos <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.194517s reading init.xml | | | | | | 0.0135735s reading info.xml | | | | | | 0.00555699s [ 0.2%] pre-initialization | | | | | | 0.0352788s [ 1.0%] initialization | | | | | | 0.000361588s [ 0.0%] steps | | | | | | 0.302928s [ 8.2%] solver (excl. callbacks) | | | | | | 0.0226478s [ 0.6%] creating output-file | | | | | | 0.0320991s [ 0.9%] event-handling | | | | | | 0.0103837s [ 0.3%] overhead | | | | | | 3.27117s [ 88.9%] simulation | | | | | | 3.68043s [100.0%] total | | | | | events | | | | | | 268 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 23735 steps taken | | | | | | 38310 calls of functionODE | | | | | | 1024 evaluations of jacobian | | | | | | 2182 error test failures | | | | | | 175 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.