Environment - simulationEnvironment: startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_latest_Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not C.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not C1.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C1." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not C2.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C2." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not C3.warnAboutOnePortConnection)) --> "Sensor TraceSubstancesFlowSource.C3 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C3." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.015242s reading init.xml | | | | | | 0.00114081s reading info.xml | | | | | | 0.000547336s [ 0.5%] pre-initialization | | | | | | 0.000431108s [ 0.4%] initialization | | | | | | 1.4076e-05s [ 0.0%] steps | | | | | | 0.00913719s [ 8.9%] solver (excl. callbacks) | | | | | | 0.00213102s [ 2.1%] creating output-file | | | | | | 4.3824e-21s [ 0.0%] event-handling | | | | | | 0.00520667s [ 5.1%] overhead | | | | | | 0.0851172s [ 82.8%] simulation | | | | | | 0.102831s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5377 steps taken | | | | | | 5602 calls of functionODE | | | | | | 98 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 3 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.