Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.AirHeater_T -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in AirHeater_T.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in AirHeater_T.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0101252s reading init.xml | | | | | | 0.000859121s reading info.xml | | | | | | 0.000537347s [ 1.7%] pre-initialization | | | | | | 0.000302878s [ 0.9%] initialization | | | | | | 2.896e-06s [ 0.0%] steps | | | | | | 0.00897497s [ 27.9%] solver (excl. callbacks) | | | | | | 0.00152204s [ 4.7%] creating output-file | | | | | | -1.2368e-20s [ -0.0%] event-handling | | | | | | 0.00427002s [ 13.3%] overhead | | | | | | 0.0165196s [ 51.3%] simulation | | | | | | 0.0321909s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 8779 steps taken | | | | | | 10185 calls of functionODE | | | | | | 160 evaluations of jacobian | | | | | | 251 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.