Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_latest_Buildings.DHC.Loads.Combined.Examples.BuildingTimeSeriesWithETSDHWTank -abortSlowSimulation -alarm=800 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/DHC/Loads/Examples/SwissOffice_20190916.mos" LOG_ASSERT | error | Model error: Argument of log(u) was -1 should be > 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((bui.ets.proHotWat.heaPumTan.pumHex.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.pumHex.eff.yMot, has value: -1.34912e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((bui.ets.proHotWat.heaPumTan.pumHex.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.pumHex.heaDis.etaHyd, has value: -2.79335e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((bui.ets.proHotWat.heaPumTan.pumHex.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.pumHex.etaHyd, has value: -9.95012e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 691.200000 | | | | ((bui.ets.proHotWat.valHeaPumEva.actPos.y >= 0.0 and bui.ets.proHotWat.valHeaPumEva.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.valHeaPumEva.actPos.y <= 1.0, has value: -1.86617e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 691.200000 | | | | ((bui.ets.proHeaWat.valHeaPumEva.actPos.y >= 0.0 and bui.ets.proHeaWat.valHeaPumEva.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.valHeaPumEva.actPos.y <= 1.0, has value: -1.86617e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.proHotWat.pumEva.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumEva.etaHyd, has value: -1.54541e-32" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.proHotWat.heaPum.m2_flow >= 0.0 and bui.ets.proHotWat.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPum.m2_flow <= 1e5, has value: -3.58037e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.pum1HexChi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.pum1HexChi.eff.yMot, has value: -2.97437e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 7823.766701 | | | | ((bui.ets.proHotWat.heaPumTan.conVal.ram.y >= 0.0 and bui.ets.proHotWat.heaPumTan.conVal.ram.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.conVal.ram.y <= 1.0, has value: -4.87182e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Reals/MultiSum.mo:9:3-11:74:writable] | | | | The following assertion has been violated at time 7823.766701 | | | | ((bui.ets.masFloHeaTot.u[2] >= 0.0 and bui.ets.masFloHeaTot.u[2] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.masFloHeaTot.u[2] <= 1e5, has value: -2.09241e-06" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 21772.800000 | | | | ((bui.ets.proHotWat.pumEva.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumEva.eff.yMot, has value: -4.76417e-59" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Chillers/BaseClasses/Carnot.mo:127:3-129:56:writable] | | | | The following assertion has been violated at time 21772.800000 | | | | ((bui.ets.proHotWat.heaPum.yPL >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPum.yPL, has value: -3.31793e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 21772.800000 | | | | ((bui.ets.proHotWat.heaPum.m1_flow >= 0.0 and bui.ets.proHotWat.heaPum.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPum.m1_flow <= 1e5, has value: -1.38778e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 21808.376152 | | | | ((bui.ets.proHotWat.heaPumTan.divVal.res3.y >= 0.0 and bui.ets.proHotWat.heaPumTan.divVal.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.divVal.res3.y <= 1.0, has value: -2.02202e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 21808.376152 | | | | ((bui.ets.proHotWat.pumCon.motSpe.y >= 0.0 and bui.ets.proHotWat.pumCon.motSpe.y <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.pumCon.motSpe.y <= 1e5, has value: -7.13075e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.ets.ports_bChiWat[1].m_flow >= -1e5 and bui.ets.ports_bChiWat[1].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= bui.ets.ports_bChiWat[1].m_flow <= 0.0, has value: 3.87886e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.ets.ports_aChiWat[1].m_flow >= 0.0 and bui.ets.ports_aChiWat[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.ports_aChiWat[1].m_flow <= 1e5, has value: -3.87886e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78:3-83:35:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.terUniCoo.hexWetNtu.SHR >= 0.0 and bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -1.92198e-88" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.terUniCoo.hexWetNtu.m2_flow >= 0.0 and bui.bui.terUniCoo.hexWetNtu.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.bui.terUniCoo.hexWetNtu.m2_flow <= 1e5, has value: -1.05077e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.terUniCoo.hexWetNtu.m1_flow >= 0.0 and bui.bui.terUniCoo.hexWetNtu.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.bui.terUniCoo.hexWetNtu.m1_flow <= 1e5, has value: -3.29953e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.bui.disFloCoo.pumFlo.etaHyd, has value: -2.04588e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/DHC/Loads/BaseClasses/FlowDistribution.mo:105:3-109:84:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.disFloCoo.mReq_flow[1] >= 0.0 and bui.bui.disFloCoo.mReq_flow[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.bui.disFloCoo.mReq_flow[1] <= 1e5, has value: -3.87886e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 28339.200000 | | | | ((bui.bui.disFloCoo.ports_a1[1].m_flow >= 0.0 and bui.bui.disFloCoo.ports_a1[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.bui.disFloCoo.ports_a1[1].m_flow <= 1e5, has value: -3.87886e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 43545.600000 | | | | ((bui.ets.proHotWat.pumCon.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumCon.eff.yMot, has value: -1.50803e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 45903.002678 | | | | ((bui.ets.proHotWat.valHeaPumEva.res3.y >= 0.0 and bui.ets.proHotWat.valHeaPumEva.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.valHeaPumEva.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 64281.600000 | | | | ((bui.ets.proHeaWat.valHeaPumEva.res3.y >= 0.0 and bui.ets.proHeaWat.valHeaPumEva.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.valHeaPumEva.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 64736.995580 | | | | ((bui.ets.proHeaWat.pumEva.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHeaWat.pumEva.etaHyd, has value: -4.36047e-31" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Reals/MultiSum.mo:9:3-11:74:writable] | | | | The following assertion has been violated at time 237475.943678 | | | | ((bui.ets.masFloHeaTot.u[1] >= 0.0 and bui.ets.masFloHeaTot.u[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.masFloHeaTot.u[1] <= 1e5, has value: -5.53371e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 237475.943678 | | | | ((bui.ets.proHeaWat.heaPum.m2_flow >= 0.0 and bui.ets.proHeaWat.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.heaPum.m2_flow <= 1e5, has value: -5.53371e-14" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.115166s reading init.xml | | | | | | 0.011106s reading info.xml | | | | | | 0.00458404s [ 0.3%] pre-initialization | | | | | | 0.0057356s [ 0.3%] initialization | | | | | | 0.000104146s [ 0.0%] steps | | | | | | 0.0960177s [ 5.5%] solver (excl. callbacks) | | | | | | 0.009451s [ 0.5%] creating output-file | | | | | | 0.0115743s [ 0.7%] event-handling | | | | | | 0.0232357s [ 1.3%] overhead | | | | | | 1.59339s [ 91.4%] simulation | | | | | | 1.74409s [100.0%] total | | | | | events | | | | | | 141 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 25554 steps taken | | | | | | 38710 calls of functionODE | | | | | | 1138 evaluations of jacobian | | | | | | 1377 error test failures | | | | | | 304 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.