Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 15552000.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | debug | ##CVODE## Desired step to small! LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 15582716.136713. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/ConservationEquation.mo:104:3-105:46:writable] | | | | The following assertion has been violated at time 15583017.600000 | | | | ((hvac.chi.vol1.dynBal.mC[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.chi.vol1.dynBal.mC[1], has value: -3.17136e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/ConservationEquation.mo:108:3-109:38:writable] | | | | The following assertion has been violated at time 15583017.600000 | | | | ((hvac.chi.vol1.dynBal.C[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.chi.vol1.dynBal.C[1], has value: -8.99854e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15616800.001562 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -5.28408e-75" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15668467.200000 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -4.02261e-317" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/HeatExchangers/BaseClasses/PartialEffectiveness.mo:17:3-23:39:writable] | | | | The following assertion has been violated at time 15668553.600000 | | | | ((hvac.cooCoi.C1_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.cooCoi.C1_flow, has value: -3.16202e-321" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/HeatExchangers/BaseClasses/PartialEffectiveness.mo:31:3-32:38:writable] | | | | The following assertion has been violated at time 15668553.600000 | | | | ((hvac.cooCoi.CMin_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.cooCoi.CMin_flow, has value: -3.16202e-321" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.132843s reading init.xml | | | | | | 0.0118356s reading info.xml | | | | | | 0.00311587s [ 0.1%] pre-initialization | | | | | | 0.0300864s [ 0.5%] initialization | | | | | | 0.000166622s [ 0.0%] steps | | | | | | 0.311328s [ 5.6%] solver (excl. callbacks) | | | | | | 0.0291774s [ 0.5%] creating output-file | | | | | | 0.154764s [ 2.8%] event-handling | | | | | | 0.0547612s [ 1.0%] overhead | | | | | | 5.00548s [ 89.6%] simulation | | | | | | 5.58888s [100.0%] total | | | | | events | | | | | | 1717 state events | | | | | | 481 time events | | | | | solver: cvode | | | | | | 25211 steps taken | | | | | | 42118 calls of functionODE | | | | | | 2231 evaluations of jacobian | | | | | | 2173 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".