Environment - simulationEnvironment: startTime=0 stopTime=5.184e+06 tolerance=1e-06 numberOfIntervals=86400 stepSize=60 Regular simulation: ./Buildings_9_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase3 -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00478338s reading init.xml | | | | | | 0.000359955s reading info.xml | | | | | | 0.000318136s [ 0.0%] pre-initialization | | | | | | 0.000126858s [ 0.0%] initialization | | | | | | 5.27e-06s [ 0.0%] steps | | | | | | 0.143395s [ 20.9%] solver (excl. callbacks) | | | | | | 0.0264438s [ 3.9%] creating output-file | | | | | | 0.00578932s [ 0.8%] event-handling | | | | | | 0.0427311s [ 6.2%] overhead | | | | | | 0.466781s [ 68.1%] simulation | | | | | | 0.68559s [100.0%] total | | | | | events | | | | | | 1444 state events | | | | | | 1440 time events | | | | | solver: cvode | | | | | | 190107 steps taken | | | | | | 196781 calls of functionODE | | | | | | 4568 evaluations of jacobian | | | | | | 35 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.