Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./Buildings_9_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeZeroFlow -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volNonLinSys.m_flow_small))) --> "In MixingVolumeZeroFlow.volNonLinSys: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volT.m_flow_small))) --> "In MixingVolumeZeroFlow.volT: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volLinSys.m_flow_small))) --> "In MixingVolumeZeroFlow.volLinSys: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volQflow.m_flow_small))) --> "In MixingVolumeZeroFlow.volQflow: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00574143s reading init.xml | | | | | | 0.00043197s reading info.xml | | | | | | 0.000331501s [ 0.9%] pre-initialization | | | | | | 0.000256531s [ 0.7%] initialization | | | | | | 4.739e-06s [ 0.0%] steps | | | | | | 4.7943e-05s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00120103s [ 3.4%] creating output-file | | | | | | 0.000636733s [ 1.8%] event-handling | | | | | | 0.00710362s [ 20.2%] overhead | | | | | | 0.0255991s [ 72.8%] simulation | | | | | | 0.0351812s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 7502 steps taken | | | | | | 7502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.