Environment - simulationEnvironment: startTime=0 stopTime=14400 tolerance=1e-06 numberOfIntervals=2500 stepSize=5.76 Regular simulation: ./Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumLoa.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumBoi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0218492s reading init.xml | | | | | | 0.00184174s reading info.xml | | | | | | 0.00077305s [ 0.7%] pre-initialization | | | | | | 0.000438342s [ 0.4%] initialization | | | | | | 2.5898e-05s [ 0.0%] steps | | | | | | 0.00930093s [ 7.9%] solver (excl. callbacks) | | | | | | 0.00273664s [ 2.3%] creating output-file | | | | | | 0.000291507s [ 0.2%] event-handling | | | | | | 0.0137318s [ 11.6%] overhead | | | | | | 0.090676s [ 76.9%] simulation | | | | | | 0.117974s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 5231 steps taken | | | | | | 5402 calls of functionODE | | | | | | 102 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.