Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_8_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithLatentGain -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senRelHum.warnAboutOnePortConnection)) --> "Sensor RoomWithLatentGain.senRelHum can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithLatentGain.senRelHum." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senMasFra.warnAboutOnePortConnection)) --> "Sensor RoomWithLatentGain.senMasFra can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithLatentGain.senMasFra." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0114805s reading init.xml | | | | | | 0.000954841s reading info.xml | | | | | | 0.00012809s [ 0.3%] pre-initialization | | | | | | 0.000184326s [ 0.4%] initialization | | | | | | 6.973e-06s [ 0.0%] steps | | | | | | 0.0117192s [ 24.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00164774s [ 3.4%] event-handling | | | | | | 0.00307099s [ 6.3%] overhead | | | | | | 0.0319755s [ 65.6%] simulation | | | | | | 0.0487329s [100.0%] total | | | | | events | | | | | | 167 state events | | | | | | 168 time events | | | | | solver: cvode | | | | | | 10314 steps taken | | | | | | 11986 calls of functionODE | | | | | | 443 evaluations of jacobian | | | | | | 35 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.