Environment - simulationEnvironment: startTime=7.776e+06 stopTime=9.504e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=691.2 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SingleFamilyHouse.RadiantHeatingCooling -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2023.12.16 06:18 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/10/2017 Continuing Simulation at 02/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/02/2017 Continuing Simulation at 03/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/22/2017 Continuing Simulation at 03/22/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/06 23:30 - 23:30 LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Dry-Bulb= -7.28 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 101.76 LOG_STDOUT | info | 7776000.000 RadiantHeatingCooling.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 7776000.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 7974600.000797 | | | | ((slaFlo.port_b.m_flow >= -1e5 and slaFlo.port_b.m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= slaFlo.port_b.m_flow <= 0.0, has value: 9.42816e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 7974600.000797 | | | | ((slaFlo.sla.m_flow >= 0.0 and slaFlo.sla.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= slaFlo.sla.m_flow <= 1e5, has value: -3.14272e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 7974600.000797 | | | | ((hea.m_flow >= 0.0 and hea.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hea.m_flow <= 1e5, has value: -9.42816e-21" Updating Shadowing Calculations, Start Date=04/11/2017 Continuing Simulation at 04/11/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.032201s reading init.xml | | | | | | 0.00351299s reading info.xml | | | | | | 0.00023962s [ 0.0%] pre-initialization | | | | | | 2.24033s [ 58.7%] initialization | | | | | | 7.1103e-05s [ 0.0%] steps | | | | | | 0.170311s [ 4.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.727532s [ 19.1%] event-handling | | | | | | 0.0362222s [ 0.9%] overhead | | | | | | 0.638674s [ 16.7%] simulation | | | | | | 3.81338s [100.0%] total | | | | | events | | | | | | 1493 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 28153 steps taken | | | | | | 40572 calls of functionODE | | | | | | 1552 evaluations of jacobian | | | | | | 558 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 3.15sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 9503400.001 RadiantHeatingCooling.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 9503400.001 RadiantHeatingCooling.building: Warning from EnergyPlus: