Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-08 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 43200.000000 | | | | ((subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 1e5, has value: -1.00627e-19" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.034534s reading init.xml | | | | | | 0.00295206s reading info.xml | | | | | | 0.000291877s [ 0.2%] pre-initialization | | | | | | 0.0326324s [ 20.9%] initialization | | | | | | 1.5068e-05s [ 0.0%] steps | | | | | | 0.00990759s [ 6.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000127282s [ 0.1%] event-handling | | | | | | 0.0236979s [ 15.2%] overhead | | | | | | 0.0894346s [ 57.3%] simulation | | | | | | 0.156107s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 6884 steps taken | | | | | | 7610 calls of functionODE | | | | | | 121 evaluations of jacobian | | | | | | 102 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.