Environment - simulationEnvironment: startTime=-1 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./Buildings_8_Buildings.Fluid.FixedResistances.Validation.PressureDropsExplicitLinearized -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00526828s reading init.xml | | | | | | 0.000543349s reading info.xml | | | | | | 7.0542e-05s [ 0.9%] pre-initialization | | | | | | 0.000180318s [ 2.2%] initialization | | | | | | 1.102e-06s [ 0.0%] steps | | | | | | 7.101e-06s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -4.14914e-21s [ -0.0%] event-handling | | | | | | 0.00177342s [ 21.5%] overhead | | | | | | 0.00619528s [ 75.2%] simulation | | | | | | 0.00823893s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 7502 steps taken | | | | | | 7502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.