Regular simulation: ./Buildings_7.0.0_Buildings.Fluid.SolarCollectors.Validation.FlatPlateNPanels -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS stdout | info | ... loading "TRNSYS" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 7.0.0/Fluid/SolarCollectors/Examples/ValidationData/TRNSYSAnnualData.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. [CVODES ERROR] CVode At t = 29713, mxstep steps taken before reaching tout. stdout | info | ##CVODE## -1 error occurred at time = 29712.9937295612 stdout | info | model terminate | Integrator failed. | Simulation terminated at time 29713 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.152077s reading init.xml | | | | | | 0.0148079s reading info.xml | | | | | | 0.000391666s [ 0.0%] pre-initialization | | | | | | 0.0514899s [ 4.5%] initialization | | | | | | 0.235368s [ 20.4%] steps | | | | | | 0.222089s [ 19.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00173733s [ 0.2%] event-handling | | | | | | 0.00581543s [ 0.5%] overhead | | | | | | 0.637047s [ 55.2%] simulation | | | | | | 1.15394s [100.0%] total | | | | | events | | | | | | 33 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 6037 steps taken | | | | | | 20186 calls of functionODE | | | | | | 124680 evaluations of jacobian | | | | | | 1505 error test failures | | | | | | 374 convergence test failures | | | | | | 0s time of jacobian evaluation