Regular simulation: ./Buildings_7.0.0_Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 7.0.0/Resources/Data/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHea.nominalValuesDefineDefaultPressureCurve or subSta.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve or subSta.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | subSta.pumChi.nominalValuesDefineDefaultPressureCurve or subSta.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 43372.800000 | | | | subSta.heaPum.m2_flow >= 0.0 and subSta.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= subSta.heaPum.m2_flow <= 100000.0, has value: -7.35895e-25 assert | warning | The following assertion has been violated at time 284601.600000 | | | | subSta.chi.m1_flow >= 0.0 and subSta.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= subSta.chi.m1_flow <= 100000.0, has value: -7.34684e-40 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0581972s reading init.xml | | | | | | 0.00591337s reading info.xml | | | | | | 0.000201649s [ 0.0%] pre-initialization | | | | | | 0.0358859s [ 7.4%] initialization | | | | | | 4.2159e-05s [ 0.0%] steps | | | | | | 0.033863s [ 7.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 8.823e-05s [ 0.0%] event-handling | | | | | | 0.0457585s [ 9.5%] overhead | | | | | | 0.36755s [ 76.0%] simulation | | | | | | 0.48339s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 11845 steps taken | | | | | | 22743 calls of functionODE | | | | | | 712 evaluations of jacobian | | | | | | 306 error test failures | | | | | | 2 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.