Regular simulation: ./Buildings_6.0.0_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase12 -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. stdout | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 86461.875000. That might raise performance issues, for more information use -lv LOG_LS. assert | debug | Solving non-linear system 155 failed at time=86460.46875. | | | | For more information please use -lv LOG_NLS. [CVODES ERROR] CVode At t = 86460, the right-hand side routine failed in an unrecoverable manner. stdout | info | ##CVODE## -8 error occurred at time = 86460 stdout | info | model terminate | Integrator failed. | Simulation terminated at time 86460 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0245547s reading init.xml | | | | | | 0.00192998s reading info.xml | | | | | | 0.000194064s [ 0.0%] pre-initialization | | | | | | 0.000216697s [ 0.0%] initialization | | | | | | 0.00233488s [ 0.0%] steps | | | | | | 0.7886s [ 8.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00052332s [ 0.0%] event-handling | | | | | | 0.00936484s [ 0.1%] overhead | | | | | | 8.06688s [ 91.0%] simulation | | | | | | 8.86811s [100.0%] total | | | | | events | | | | | | 24 state events | | | | | | 24 time events | | | | | solver: cvode | | | | | | 152461 steps taken | | | | | | 618484 calls of functionODE | | | | | | 693675 evaluations of jacobian | | | | | | 860 error test failures | | | | | | 102462 convergence test failures | | | | | | 0s time of jacobian evaluation