Regular simulation: ./Buildings_6.0.0_Buildings.Experimental.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/Data/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/Data/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgStand-aloneRetailNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/Data/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgMidriseApartmentNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHea.nominalValuesDefineDefaultPressureCurve or larOff1.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHotWat.nominalValuesDefineDefaultPressureCurve or larOff1.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumChi.nominalValuesDefineDefaultPressureCurve or larOff1.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHea.nominalValuesDefineDefaultPressureCurve or ret1.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHotWat.nominalValuesDefineDefaultPressureCurve or ret1.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumChi.nominalValuesDefineDefaultPressureCurve or ret1.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHea.nominalValuesDefineDefaultPressureCurve or larOff2.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHotWat.nominalValuesDefineDefaultPressureCurve or larOff2.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumChi.nominalValuesDefineDefaultPressureCurve or larOff2.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHea.nominalValuesDefineDefaultPressureCurve or apa1.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHotWat.nominalValuesDefineDefaultPressureCurve or apa1.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumChi.nominalValuesDefineDefaultPressureCurve or apa1.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHea.nominalValuesDefineDefaultPressureCurve or larOff3.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHotWat.nominalValuesDefineDefaultPressureCurve or larOff3.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumChi.nominalValuesDefineDefaultPressureCurve or larOff3.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHea.nominalValuesDefineDefaultPressureCurve or larOff4.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHotWat.nominalValuesDefineDefaultPressureCurve or larOff4.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumChi.nominalValuesDefineDefaultPressureCurve or larOff4.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHea.nominalValuesDefineDefaultPressureCurve or apa2.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHotWat.nominalValuesDefineDefaultPressureCurve or apa2.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumChi.nominalValuesDefineDefaultPressureCurve or apa2.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHea.nominalValuesDefineDefaultPressureCurve or ret2.pumHea.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHotWat.nominalValuesDefineDefaultPressureCurve or ret2.pumHotWat.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumChi.nominalValuesDefineDefaultPressureCurve or ret2.pumChi.per.havePressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 14400.000001 | | | | weaDat.totSkyCov_in_internal >= 0.0 and weaDat.totSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.totSkyCov_in_internal <= 1.0, has value: -2.40281e-11 assert | warning | The following assertion has been violated at time 14400.000001 | | | | weaDat.opaSkyCov_in_internal >= 0.0 and weaDat.opaSkyCov_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.opaSkyCov_in_internal <= 1.0, has value: -2.40281e-11 assert | warning | The following assertion has been violated at time 46800.000005 | | | | larOff1.heaPum.m2_flow >= 0.0 and larOff1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.heaPum.m2_flow <= 100000.0, has value: -3.60102e-78 assert | warning | The following assertion has been violated at time 46800.000005 | | | | larOff2.heaPum.m2_flow >= 0.0 and larOff2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff2.heaPum.m2_flow <= 100000.0, has value: -3.60102e-78 assert | warning | The following assertion has been violated at time 46800.000005 | | | | larOff3.heaPum.m2_flow >= 0.0 and larOff3.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.heaPum.m2_flow <= 100000.0, has value: -3.60102e-78 assert | warning | The following assertion has been violated at time 46800.000005 | | | | larOff4.heaPum.m2_flow >= 0.0 and larOff4.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.heaPum.m2_flow <= 100000.0, has value: -3.60102e-78 assert | warning | The following assertion has been violated at time 75600.000008 | | | | ret1.heaPum.m2_flow >= 0.0 and ret1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.heaPum.m2_flow <= 100000.0, has value: -1.96912e-16 assert | warning | The following assertion has been violated at time 75600.000008 | | | | ret2.heaPum.m2_flow >= 0.0 and ret2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret2.heaPum.m2_flow <= 100000.0, has value: -1.96912e-16 assert | warning | The following assertion has been violated at time 284400.000028 | | | | larOff1.chi.m1_flow >= 0.0 and larOff1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.chi.m1_flow <= 100000.0, has value: -2.93874e-39 assert | warning | The following assertion has been violated at time 284400.000028 | | | | larOff2.chi.m1_flow >= 0.0 and larOff2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff2.chi.m1_flow <= 100000.0, has value: -2.93874e-39 assert | warning | The following assertion has been violated at time 284400.000028 | | | | larOff3.chi.m1_flow >= 0.0 and larOff3.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.chi.m1_flow <= 100000.0, has value: -2.93874e-39 assert | warning | The following assertion has been violated at time 284400.000028 | | | | larOff4.chi.m1_flow >= 0.0 and larOff4.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.chi.m1_flow <= 100000.0, has value: -2.93874e-39 assert | warning | The following assertion has been violated at time 316800.000032 | | | | ret1.chi.m1_flow >= 0.0 and ret1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.chi.m1_flow <= 100000.0, has value: -3.85186e-34 assert | warning | The following assertion has been violated at time 349200.000035 | | | | apa1.chi.m1_flow >= 0.0 and apa1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa1.chi.m1_flow <= 100000.0, has value: -3.00927e-36 assert | warning | The following assertion has been violated at time 349200.000035 | | | | apa2.chi.m1_flow >= 0.0 and apa2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa2.chi.m1_flow <= 100000.0, has value: -3.00927e-36 assert | warning | The following assertion has been violated at time 514800.000051 | | | | weaBus.nOpa >= 0.0 and weaBus.nOpa <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaBus.nOpa <= 1.0, has value: 1 assert | warning | The following assertion has been violated at time 514800.000051 | | | | weaBus.nTot >= 0.0 and weaBus.nTot <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaBus.nTot <= 1.0, has value: 1 assert | warning | The following assertion has been violated at time 514800.000051 | | | | weaDat.TBlaSkyCom.nOpa10 >= 0.0 and weaDat.TBlaSkyCom.nOpa10 <= 10.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.TBlaSkyCom.nOpa10 <= 10.0, has value: 10 assert | warning | The following assertion has been violated at time 529200.000053 | | | | weaDat.relHum_in_internal >= 0.0 and weaDat.relHum_in_internal <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.relHum_in_internal <= 1.0, has value: 1 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.405962s reading init.xml | | | | | | 0.0424413s reading info.xml | | | | | | 0.000571544s [ 0.0%] pre-initialization | | | | | | 0.050752s [ 0.3%] initialization | | | | | | 0.000850777s [ 0.0%] steps | | | | | | 0.464043s [ 2.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.83128s [ 14.0%] event-handling | | | | | | 0.679995s [ 3.4%] overhead | | | | | | 16.1974s [ 80.1%] simulation | | | | | | 20.2249s [100.0%] total | | | | | events | | | | | | 8760 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 75229 steps taken | | | | | | 142828 calls of functionODE | | | | | | 43810 evaluations of jacobian | | | | | | 3653 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.