Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation (cvode: SUNDIALS CVODE): (cd run_cvode && ../Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalOneZoneBuildings -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s cvode) EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.22 14:05 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[2].duc.m_flow >= 0.0 and bui[2].duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui[2].duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[1].duc.m_flow >= 0.0 and bui[1].duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui[1].duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0109391s reading init.xml | | | | | | 0.00104402s reading info.xml | | | | | | 0.000132499s [ 0.0%] pre-initialization | | | | | | 5.25578s [ 98.7%] initialization | | | | | | 0.000181822s [ 0.0%] steps | | | | | | 0.0030007s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0489032s [ 0.9%] event-handling | | | | | | 0.00276567s [ 0.1%] overhead | | | | | | 0.0126645s [ 0.2%] simulation | | | | | | 5.32343s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 288 time events | | | | | solver: cvode | | | | | | 1980 steps taken | | | | | | 3350 calls of functionODE | | | | | | 288 evaluations of jacobian | | | | | | 231 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00106391s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.22sec EnergyPlus Completed Successfully.