Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=120 stepSize=3600 Regular simulation: ./Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV -abortSlowSimulation -alarm=400 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | debug | ##CVODE## Desired step to small! LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15668280.102480 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -5.04871e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15705840.531735 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -1.00974e-28" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.198622s reading init.xml | | | | | | 0.0127366s reading info.xml | | | | | | 0.00433711s [ 0.2%] pre-initialization | | | | | | 0.0364746s [ 1.8%] initialization | | | | | | 0.00237372s [ 0.1%] steps | | | | | | 0.113908s [ 5.5%] solver (excl. callbacks) | | | | | | 0.0118452s [ 0.6%] creating output-file | | | | | | 0.0491011s [ 2.4%] event-handling | | | | | | 0.00898641s [ 0.4%] overhead | | | | | | 1.83605s [ 89.0%] simulation | | | | | | 2.06307s [100.0%] total | | | | | events | | | | | | 80 state events | | | | | | 481 time events | | | | | solver: cvode | | | | | | 9818 steps taken | | | | | | 15473 calls of functionODE | | | | | | 592 evaluations of jacobian | | | | | | 623 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".