Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow -abortSlowSimulation -alarm=400 -s cvode -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 1980.000000 | | | | ((hex.SHR >= 0.0 and hex.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hex.SHR <= 1.0, has value: -4.23764e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:356:5-365:38:writable] | | | | The following assertion has been violated at time 1998.720000 | | | | ((noEvent(hex.m1_flow > (-0.1) * hex.m1_flow_nominal) and noEvent(hex.m2_flow > (-0.1) * hex.m2_flow_nominal))) --> "*** Warning in WetCoilEffectivenessNTUMassFlow.hex: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-21379.4)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-21379.4)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-21379.4)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:2005: Invalid root: (0)^(-1.5) LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 2520. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-12133.9)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-12133.9)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:1995: Invalid root: (-12133.9)^(-1.5) LOG_ASSERT | debug | Buildings_12_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow_functions.c:2005: Invalid root: (0)^(-1.5) LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 2519.38. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0123977s reading init.xml | | | | | | 0.000877395s reading info.xml | | | | | | 0.000684474s [ 1.9%] pre-initialization | | | | | | 0.000327534s [ 0.9%] initialization | | | | | | 8.386e-06s [ 0.0%] steps | | | | | | 0.00282516s [ 7.7%] solver (excl. callbacks) | | | | | | 0.00124101s [ 3.4%] creating output-file | | | | | | 8.0366e-05s [ 0.2%] event-handling | | | | | | 0.00558823s [ 15.2%] overhead | | | | | | 0.025962s [ 70.7%] simulation | | | | | | 0.0367171s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2814 steps taken | | | | | | 2978 calls of functionODE | | | | | | 51 evaluations of jacobian | | | | | | 24 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.