Environment - simulationEnvironment: startTime=0 stopTime=360 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.144 Regular simulation: ./Buildings_12_Buildings.Applications.BaseClasses.Equipment.Validation.PumpParallel -abortSlowSimulation -alarm=400 -s cvode -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:84:3-85:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pumPar2.threshold >= 0.01)) --> "Variable violating min constraint: 0.01 <= pumPar2.threshold, has value: 0.0002" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:84:3-85:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pumPar1.threshold >= 0.01)) --> "Variable violating min constraint: 0.01 <= pumPar1.threshold, has value: 0.0001" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((pumPar1.pum[1].eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumPar1.pum[1].eta, has value: -3.16588e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((pumPar1.pum[1].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumPar1.pum[1].eff.yMot, has value: -4.03071e-31" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((pumPar1.pum[2].eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumPar1.pum[2].eta, has value: -7.94555e-32" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((pumPar1.pum[2].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumPar1.pum[2].eff.yMot, has value: -1.0116e-33" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0418589s reading init.xml | | | | | | 0.0037139s reading info.xml | | | | | | 0.00127065s [ 2.4%] pre-initialization | | | | | | 0.00122347s [ 2.3%] initialization | | | | | | 8.697e-06s [ 0.0%] steps | | | | | | 0.00374056s [ 7.2%] solver (excl. callbacks) | | | | | | 0.00224192s [ 4.3%] creating output-file | | | | | | 0.000321243s [ 0.6%] event-handling | | | | | | 0.00621254s [ 11.9%] overhead | | | | | | 0.0371176s [ 71.2%] simulation | | | | | | 0.0521366s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2803 steps taken | | | | | | 3032 calls of functionODE | | | | | | 58 evaluations of jacobian | | | | | | 46 error test failures | | | | | | 4 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.