Environment - simulationEnvironment: startTime=0 stopTime=2.592e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=1036.8 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.BaseClasses.ZoneSurfaces -abortSlowSimulation -alarm=400 -s cvode -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.12.21 07:23 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Warming up {13} Warming up {14} Warming up {15} Warming up {16} Warming up {17} Warming up {18} Warming up {19} Warming up {20} Warming up {21} Warming up {22} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output ZoneSurfaces.TGarAir.y has in Modelica the unit K. LOG_STDOUT | info | Output ZoneSurfaces.TIntWalLivSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ZoneSurfaces.TIntWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ZoneSurfaces.TWesWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ZoneSurfaces.TEasWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ZoneSurfaces.wes.extSurHea.y has in Modelica the unit W. LOG_STDOUT | info | Output ZoneSurfaces.eas.extSurHea.y has in Modelica the unit W. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0199645s reading init.xml | | | | | | 0.00196081s reading info.xml | | | | | | 0.000224631s [ 0.0%] pre-initialization | | | | | | 8.14849s [ 76.7%] initialization | | | | | | 5.2519e-05s [ 0.0%] steps | | | | | | 0.0990889s [ 0.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.08277s [ 19.6%] event-handling | | | | | | 0.0162447s [ 0.2%] overhead | | | | | | 0.276136s [ 2.6%] simulation | | | | | | 10.623s [100.0%] total | | | | | events | | | | | | 4319 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 34013 steps taken | | | | | | 57071 calls of functionODE | | | | | | 4320 evaluations of jacobian | | | | | | 7 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 2.95sec EnergyPlus Completed Successfully.