Environment - simulationEnvironment: startTime=0 stopTime=2.592e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=1036.8 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.BaseClasses.ReferenceSurfaces -abortSlowSimulation -alarm=400 -s cvode -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.12.21 07:23 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Warming up {13} Warming up {14} Warming up {15} Warming up {16} Warming up {17} Warming up {18} Warming up {19} Warming up {20} Warming up {21} Warming up {22} Warming up {23} Warming up {24} Warming up {25} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output ReferenceSurfaces.TIntWalLivSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ReferenceSurfaces.TIntWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ReferenceSurfaces.TWesWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ReferenceSurfaces.TEasWalGarSur.y has in Modelica the unit K. LOG_STDOUT | info | Output ReferenceSurfaces.TGarAir.y has in Modelica the unit K. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00459047s reading init.xml | | | | | | 0.000449152s reading info.xml | | | | | | 4.9543e-05s [ 0.0%] pre-initialization | | | | | | 8.45824s [ 86.7%] initialization | | | | | | 1.874e-06s [ 0.0%] steps | | | | | | 0.000132057s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.26679s [ 13.0%] event-handling | | | | | | 0.0133932s [ 0.1%] overhead | | | | | | 0.0200257s [ 0.2%] simulation | | | | | | 9.75864s [100.0%] total | | | | | events | | | | | | 4319 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 14732459 steps taken | | | | | | 14732459 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 1.97sec EnergyPlus Completed Successfully.