Environment - simulationEnvironment: startTime=0 stopTime=20000 tolerance=1e-06 numberOfIntervals=2500 stepSize=8 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.Borefield -abortSlowSimulation -alarm=480 -s cvode -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/43298c6bc5a238dc508704c7065779869a7e90d9TStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/43298c6bc5a238dc508704c7065779869a7e90d9TStep.mat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Borefield.borFie.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.0-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((borFie.pum.per.haveWMot_nominal or not (borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Borefield.borFie.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/43298c6bc5a238dc508704c7065779869a7e90d9TStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/43298c6bc5a238dc508704c7065779869a7e90d9TStep.mat" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | debug | ##CVODE## Desired step to small! LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.150359s reading init.xml | | | | | | 0.0109482s reading info.xml | | | | | | 0.00511152s [ 0.0%] pre-initialization | | | | | | 42.3664s [ 99.3%] initialization | | | | | | 3.8473e-05s [ 0.0%] steps | | | | | | 0.0269147s [ 0.1%] solver (excl. callbacks) | | | | | | 0.0139852s [ 0.0%] creating output-file | | | | | | 0.003324s [ 0.0%] event-handling | | | | | | 0.0306237s [ 0.1%] overhead | | | | | | 0.202469s [ 0.5%] simulation | | | | | | 42.6489s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 67 time events | | | | | solver: cvode | | | | | | 5417 steps taken | | | | | | 5763 calls of functionODE | | | | | | 142 evaluations of jacobian | | | | | | 8 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.