Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in AirToWater2D_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/ModularReversible/TableData2D.mo:78:3-83:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(heaPum.scaFacHea - heaPum.scaFacCoo) / heaPum.scaFacHea < heaPum.limWarSca)) --> "In AirToWater2D_OneRoomRadiator.heaPum: Scaling factors for heating and cooling | | | | operation differ by -17.4444 %. The simulated nominal heating and cooling | | | | capacities may not be realistic for a single device" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.054044s reading init.xml | | | | | | 0.00451455s reading info.xml | | | | | | 0.000243166s [ 0.1%] pre-initialization | | | | | | 0.0318194s [ 7.0%] initialization | | | | | | 4.1117e-05s [ 0.0%] steps | | | | | | 0.0507952s [ 11.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00880173s [ 1.9%] event-handling | | | | | | 0.0176074s [ 3.9%] overhead | | | | | | 0.345876s [ 76.0%] simulation | | | | | | 0.455184s [100.0%] total | | | | | events | | | | | | 259 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 17964 steps taken | | | | | | 23463 calls of functionODE | | | | | | 449 evaluations of jacobian | | | | | | 566 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.