Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./BuildingSystems_BuildingSystems.Applications.HeatingSystems.WaterHeatingSystem -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in WaterHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in WaterHeatingSystem.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in WaterHeatingSystem.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Airvolumes/AirvolumeMixed.mo:15:3-15:74:writable] | | | | The following assertion has been violated at time 6307.200000 | | | | ((building.zone.airvolume.mH2OLiq >= 0.0)) --> "Variable violating min constraint: 0.0 <= building.zone.airvolume.mH2OLiq, has value: -5.16628e-18" LOG_STDOUT | info | ##CVODE## -1 error occurred at time = 11779.944478976 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 11779.9 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.153131s reading init.xml | | | | | | 0.00721939s reading info.xml | | | | | | 0.00122457s [ 0.4%] pre-initialization | | | | | | 0.00793702s [ 2.4%] initialization | | | | | | 0.12877s [ 38.6%] steps | | | | | | 0.0139025s [ 4.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000226244s [ 0.1%] event-handling | | | | | | 8.3618e-05s [ 0.0%] overhead | | | | | | 0.181175s [ 54.4%] simulation | | | | | | 0.333318s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 2481 steps taken | | | | | | 3286 calls of functionODE | | | | | | 46 evaluations of jacobian | | | | | | 169 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation