Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Airvolumes/AirvolumeMixed.mo:15:3-15:74:writable] | | | | The following assertion has been violated at time 3165.447338 | | | | ((building.zone.airvolume.mH2OLiq >= 0.0)) --> "Variable violating min constraint: 0.0 <= building.zone.airvolume.mH2OLiq, has value: -1.35098e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:175:3-177:124:writable] | | | | The following assertion has been violated at time 1166832.000000 | | | | ((ambience.cloudCover >= 0.0 and ambience.cloudCover <= 8.0)) --> "Variable violating min/max constraint: 0.0 <= ambience.cloudCover <= 8.0, has value: 8.2356" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 6414422.400000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.01016" LOG_ASSERT | debug | Solving non-linear system 3908 failed at time=12440330.4169273. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | info | ##CVODE## -8 error occurred at time = 12439884.4494321 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 1.24399e+07 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.161025s reading init.xml | | | | | | 0.00745509s reading info.xml | | | | | | 0.00101312s [ 0.0%] pre-initialization | | | | | | 0.00788115s [ 0.1%] initialization | | | | | | 0.00297409s [ 0.0%] steps | | | | | | 0.540576s [ 3.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0205516s [ 0.1%] event-handling | | | | | | 0.04986s [ 0.4%] overhead | | | | | | 13.2519s [ 95.5%] simulation | | | | | | 13.8748s [100.0%] total | | | | | events | | | | | | 154 state events | | | | | | 0 time events | | | | | solver: cvode | | | | | | 88908 steps taken | | | | | | 120548 calls of functionODE | | | | | | 1729 evaluations of jacobian | | | | | | 4258 error test failures | | | | | | 3 convergence test failures | | | | | | 0s time of jacobian evaluation