Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain -abortSlowSimulation -alarm=480 -s cvode -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senRelHum.warnAboutOnePortConnection)) --> "Sensor RoomWithoutLatentGain.senRelHum can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senRelHum." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senMasFra.warnAboutOnePortConnection)) --> "Sensor RoomWithoutLatentGain.senMasFra can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senMasFra." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.012299s reading init.xml | | | | | | 0.000854453s reading info.xml | | | | | | 0.000172654s [ 0.3%] pre-initialization | | | | | | 0.000231093s [ 0.4%] initialization | | | | | | 1.3074e-05s [ 0.0%] steps | | | | | | 0.0126353s [ 23.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00178537s [ 3.3%] event-handling | | | | | | 0.00378008s [ 7.1%] overhead | | | | | | 0.0348427s [ 65.2%] simulation | | | | | | 0.0534603s [100.0%] total | | | | | events | | | | | | 167 state events | | | | | | 168 time events | | | | | solver: cvode | | | | | | 10160 steps taken | | | | | | 11807 calls of functionODE | | | | | | 441 evaluations of jacobian | | | | | | 32 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.